Ontap Hardware Issues
Ontap Hardware Issues
Featured
Support for BlueXP Backup and Recovery
Learn how MetroCluster works, why it’s important to back up your data, and how BlueXP backup and recovery can help.
Learn how MetroCluster works, why it’s important to back up your data, and how BlueXP backup and recovery can help.
Recommended component releases
List of recommended component releases per your ONTAP OS version.
List of recommended component releases per your ONTAP OS version.
Benefits of managing ATTO bridges in-band
Items to consider on the benefits of using ATTO bridges in-band.
Items to consider on the benefits of using ATTO bridges in-band.
How to use the RcfFileGenerator for MetroCluster IP
A detailed guide on how to use the RcfFileGenerator for MetroCluster IP.
A detailed guide on how to use the RcfFileGenerator for MetroCluster IP.
Useful commands for MetroCluster FC and IP switches
The most commonly used commands for configuring, managing and troubleshooting MetroCluster switches.
The most commonly used commands for configuring, managing and troubleshooting MetroCluster switches.
Upgrade switch RCF's without wiping the switch"
Documentation guide to upgrade an RCF file on a Cisco IP switch.
Documentation guide to upgrade an RCF file on a Cisco IP switch.
Other Resources
- CFDISK-1011: NA02 firmware release for the *HARHE model drivesFri, 11 Oct 2024
- CONTAP-229912: debug seqid show does not work with domain user using ZAPI to CLI commandThu, 10 Oct 2024
- CONTAP-323624: ERR: Servprocd::CLI: bezel_led_get_imp: sp_bezel_led_iterator::bezel_led_get called error message when executing bezel-led- mgwdThu, 10 Oct 2024
- CONTAP-290235: Cluster switch logs not captured in daily Autosupport logsThu, 10 Oct 2024
- CFBMC-2639: AFF A900, FAS9500: BMC 16.4 and lower reports PCH Temp sensor as unreadable when BIOS 18.9 is installedWed, 09 Oct 2024
- CHW-2456: Fan fails with error message on AFF A250 or FAS500f systemsWed, 09 Oct 2024
- CONTAP-326969: Reliability improvements in new HUS72* and WVELE* drive firmwareTue, 08 Oct 2024
- CHW-2756: ANDU on AFF-A900 to 9.13.1P7 might pause due to prolonged firmware upgrade of the NVS moduleMon, 07 Oct 2024
- CONTAP-320072: System runs out of memory when running stress test with 3 or more X50133A IO modulesThu, 03 Oct 2024
- CONTAP-322297: SNMP query to IPv6 address on NVIDIA MSN2100 Switch running Cumulus Linux 5.X is not respondingWed, 02 Oct 2024
- CONTAP-38919: Unexpected SNMP requests from ONTAP cluster sent to cluster IPspace or neighbor switches on the management networkTue, 01 Oct 2024
- CONTAP-52106: System-level HW diagnostics fail to identify X1148A 100GbE NICTue, 01 Oct 2024
- CONTAP-77936: The node halts instead of rebooting if shutdown takes too long during an automated nondisruptive upgradeTue, 01 Oct 2024
- CONTAP-303498: ONTAP cluster node reboots unexpectedlyMon, 30 Sep 2024
- CONTAP-308073: ONTAP cluster node reboots unexpectedlyFri, 27 Sep 2024
- CONTAP-278402: The Service Processor(SP) is reporting there is an error updating the SP user informationFri, 27 Sep 2024
- CHW-915: Bug public information is not yet available.Thu, 26 Sep 2024
- CHW-2739: AFF A700s: page fault (supervisor read instruction, page not present) on VA 0 cs:rip 0x20:0 rflags 0x10206 in process swi1: mri_haWed, 25 Sep 2024
- CFLOADER-902: MetroCluster IP bootargs/SMDB table entries missing after ONTAP upgradeWed, 25 Sep 2024
- CONTAP-311231: The local node rebooted without initiating a takeover by it's partner nodeTue, 24 Sep 2024
- CFDISK-1011: NA02 firmware release for the *HARHE model drivesFri, 11 Oct 2024
- CFDISK-450: X357_TPM4V3T8AME NA51 and X356_TPM4V3T8AME NA01 fail upon initializationFri, 11 Oct 2024
- CONTAP-323624: ERR: Servprocd::CLI: bezel_led_get_imp: sp_bezel_led_iterator::bezel_led_get called error message when executing bezel-led- mgwdFri, 11 Oct 2024
- ONTAP Select drives show up mixed type SSD or VMDISKFri, 11 Oct 2024
- CONTAP-303498: ONTAP cluster node reboots unexpectedlyFri, 11 Oct 2024
- CONTAP-207251: ClusterSwitchConnectivity_Alert incorrectly triggered when cluster switch name differs from CDP/LLDPFri, 11 Oct 2024
- CONTAP-229912: debug seqid show does not work with domain user using ZAPI to CLI commandThu, 10 Oct 2024
- CONTAP-290235: Cluster switch logs not captured in daily Autosupport logsThu, 10 Oct 2024
- CFBMC-2639: AFF A900, FAS9500: BMC 16.4 and lower reports PCH Temp sensor as unreadable when BIOS 18.9 is installedWed, 09 Oct 2024
- CFBMC-3996: Node reboots due to SP HBT STOPPED on BMC 13.10P1Wed, 09 Oct 2024
- CONTAP-97627: Enhancements for System-Level HW Diagnostics 07.02.03Wed, 09 Oct 2024
- CONTAP-52106: System-level HW diagnostics fail to identify X1148A 100GbE NICWed, 09 Oct 2024
- CHW-2456: Fan fails with error message on AFF A250 or FAS500f systemsWed, 09 Oct 2024
- CONTAP-326969: Reliability improvements in new HUS72* and WVELE* drive firmwareTue, 08 Oct 2024
- CONTAP-249770: NVIDIA SN2100 switches shown as "unsupported"Tue, 08 Oct 2024
- CHW-2472: AFF A250/AFF C250 and FAS500f experience non responsive CPUs followed by watchdog controller disruptionsTue, 08 Oct 2024
- CHW-2756: ANDU on AFF-A900 to 9.13.1P7 might pause due to prolonged firmware upgrade of the NVS moduleMon, 07 Oct 2024
- CONTAP-320072: System runs out of memory when running stress test with 3 or more X50133A IO modulesSat, 05 Oct 2024
- CONTAP-163300: SwitchReboot_Alert not clearedSat, 05 Oct 2024
- CONTAP-293836: Enhancements for BIOS 20.2.2 and LOADER 8.3.0Sat, 05 Oct 2024
Highest rated
(rating)- ClusterIfIslDownWarn_Alert post ONTAP 9.11.1P5+ upgrade due to unused ISL ports
- BMC not responding, error: FAILED : smf_sp_network_status_get for IPv4 or v6
- ONTAP Select drives show up mixed type SSD or VMDISK
- NVIDIA SN2100 switch fails to connect using 40/100GbE copper cable
- CFBMC-3952: SP heatbeat stopped on BMC version 15.11
- CHW-588: AFF A400, FAS8300, FAS8700: Cannot boot with primary firmware image
- CONTAP-246043: Environment sensors show command returns Warning: Unable to list entries on node
- CONTAP-28903: ONTAP Node reboots unexpectedly with error WAFL hung for aggr_name. in SK process wafl_exempt02
- CFBMC-3251: Many IO cards are reported as degraded and recovered by BMC reboot
- CHW-1433: AFF-A800 disruption caused by watchdog nmi on CPU events
- CHW-1885: AFF A320: "CHASSIS POWER SUPPLY NEED TO BE REPLACED" AutoSupport after PSU replacement
- CHW-489: Tracking: A400/FAS8300(CHASSIS OVER TEMPERATURE) ERROR warnings
- CHW-2472: AFF A250/AFF C250 and FAS500f experience non responsive CPUs followed by watchdog controller disruptions
- CHW-2504: FAS8200 repeatidly reports 'CHASSIS POWER SUPPLY DEGRADED' even after PSU replacement
- CFBMC-609: Temperature-based policy implemented for multiple fan failures on HA systems with shared cooling
Recently updated
(date updated)- CFDISK-1011: NA02 firmware release for the *HARHE model drives
- CFDISK-450: X357_TPM4V3T8AME NA51 and X356_TPM4V3T8AME NA01 fail upon initialization
- CONTAP-323624: ERR: Servprocd::CLI: bezel_led_get_imp: sp_bezel_led_iterator::bezel_led_get called error message when executing bezel-led- mgwd
- ONTAP Select drives show up mixed type SSD or VMDISK
- CONTAP-303498: ONTAP cluster node reboots unexpectedly
- CONTAP-207251: ClusterSwitchConnectivity_Alert incorrectly triggered when cluster switch name differs from CDP/LLDP
- CONTAP-229912: debug seqid show does not work with domain user using ZAPI to CLI command
- CONTAP-290235: Cluster switch logs not captured in daily Autosupport logs
- CFBMC-2639: AFF A900, FAS9500: BMC 16.4 and lower reports PCH Temp sensor as unreadable when BIOS 18.9 is installed
- CFBMC-3996: Node reboots due to SP HBT STOPPED on BMC 13.10P1
- CONTAP-97627: Enhancements for System-Level HW Diagnostics 07.02.03
- CONTAP-52106: System-level HW diagnostics fail to identify X1148A 100GbE NIC
- CHW-2456: Fan fails with error message on AFF A250 or FAS500f systems
- CONTAP-326969: Reliability improvements in new HUS72* and WVELE* drive firmware
- CONTAP-249770: NVIDIA SN2100 switches shown as "unsupported"
Recently added
(date created)- CFDISK-1011: NA02 firmware release for the *HARHE model drives
- CONTAP-229912: debug seqid show does not work with domain user using ZAPI to CLI command
- CONTAP-323624: ERR: Servprocd::CLI: bezel_led_get_imp: sp_bezel_led_iterator::bezel_led_get called error message when executing bezel-led- mgwd
- CONTAP-290235: Cluster switch logs not captured in daily Autosupport logs
- CFBMC-2639: AFF A900, FAS9500: BMC 16.4 and lower reports PCH Temp sensor as unreadable when BIOS 18.9 is installed
- CHW-2456: Fan fails with error message on AFF A250 or FAS500f systems
- CONTAP-326969: Reliability improvements in new HUS72* and WVELE* drive firmware
- CHW-2756: ANDU on AFF-A900 to 9.13.1P7 might pause due to prolonged firmware upgrade of the NVS module
- CONTAP-320072: System runs out of memory when running stress test with 3 or more X50133A IO modules
- CONTAP-322297: SNMP query to IPv6 address on NVIDIA MSN2100 Switch running Cumulus Linux 5.X is not responding
- CONTAP-38919: Unexpected SNMP requests from ONTAP cluster sent to cluster IPspace or neighbor switches on the management network
- CONTAP-52106: System-level HW diagnostics fail to identify X1148A 100GbE NIC
- CONTAP-77936: The node halts instead of rebooting if shutdown takes too long during an automated nondisruptive upgrade
- CONTAP-303498: ONTAP cluster node reboots unexpectedly
- CONTAP-308073: ONTAP cluster node reboots unexpectedly