ONTAP Hardware
ONTAP Hardware
Featured
Automatic Firmware download Feature
The Automatic Update feature allows ONTAP to automatically download and install recommended firmware
The Automatic Update feature allows ONTAP to automatically download and install recommended firmware
How to perform a health check
A Resolutiom guide of various methods to check the health of your system
A Resolutiom guide of various methods to check the health of your system
Shutdown and Power up procedures
Best practices and procedures to perform a graceful shutdown and power up your ONTAP cluster
Best practices and procedures to perform a graceful shutdown and power up your ONTAP cluster
Controller hardware upgrade Resolution guide
This guide describes how to upgrade controller hardware of an AFF system or a FAS system in a cluster by moving storage or volumes
This guide describes how to upgrade controller hardware of an AFF system or a FAS system in a cluster by moving storage or volumes
Service Processor (SP) & Baseboard Management Controller (BMC) Resolution Guide
Collection of solutions for your SP or BMC questions
Collection of solutions for your SP or BMC questions
DISK FAILED process
Provides guidance around the disk failure process
Provides guidance around the disk failure process
Other Resources
- CHW-2395: A800 reboots unexpectedly with error unrecoverable error on internal PCIe switchDec, 2024
- msata.unable.to.monitor error shown in EMSDec, 2024
- FA9500/AFF-A900 sysconfig: Card in slot X (1-15xx-xx1B-0) is not supported when rebootDec, 2024
- CFBMC-5907: BMC Port Fluctuations Post-Upgrade to Version 10.9+ Causes Flapping of Wrench PortDec, 2024
- CFBMC-3955: Undertemperature warnings after BMC firmware upgradeDec, 2024
- SAS Adapter port shows as rate unknown for one PHY (Internal shelf) due to Partner MBDec, 2024
- SAS Adapter port shows as rate unknown for one PHY (Internal shelf)Dec, 2024
- How to use AutoSupport information for prerequisite data collection in FRU replacements when ONTAP systems will not bootDec, 2024
- CFDISK-974: NE12/MS12 firmware for WD Cobra-F drivesDec, 2024
- EMS log reports "scsi cmd checkCondition" error on diskDec, 2024
- SwitchIslIfDownWarn_Alert reported for MCC-IP ISL portsDec, 2024
- CONTAP-338515: SP 4.11P2 includes enhancements for AFF A700 and FAS9000 systemsDec, 2024
- CONTAP-355735: "Failed to discover SNMPv3 engine ID of remote SNMP agent" in one side of a MCC IPDec, 2024
- CONTAP-348151: One path to NVMe drive is missing after being inserted into a controller's drive bayDec, 2024
- CONTAP-164509: During motherboard replacement, 0 disks found, no root volume foundDec, 2024
- CONTAP-163300: SwitchReboot_Alert not clearedDec, 2024
- CONTAP-249770: NVIDIA SN2100 switches shown as "unsupported"Dec, 2024
- CONTAP-250835: X91440A NIC fails after a firmware update in ONTAP 9.13.1Dec, 2024
- CONTAP-97627: Enhancements for System-Level HW Diagnostics 07.02.03Dec, 2024
- CONTAP-229912: debug seqid show does not work with domain user using ZAPI to CLI commandDec, 2024
- How to identify a failed disk prior to replacement
- How to perform an IOM removal/replacement
- Cluster hw_assist: hw_assist functionality is inactive - How to configure hw_assist
- How to update the Service Processor firmware when a Web server is unavailable
- How to determine the disk and shelf firmware version on a controller and verify it is up-to-date
- How to use RLM to collect data required to troubleshoot a hardware issue
- How to change disk ownership between two heads on FAS2000 or FAS3000 series controllers