ONTAP might incorrectly alert for nvmem.battery.chgrFailed event in the following specific conditions:

  1. Erroneously trigger when the NVDIMM battery is in a learning cycle.
  2. Fail to trigger when the NVDIMM battery charger is completely non-operational.
  3. If the NVDIMM battery charger is charging and the NVDIMM battery is discharging for five minutes, instead of triggering the event the system will shutdown in twenty minutes.

EMS log:
[monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery current critical)
Applies only to the following exact ONTAP versions:
  • 9.16.1
  • 9.16.1RC1
  • 9.15.1P7
  • 9.15.1P6
  • 9.15.1P5
  • 9.14.1P11
  • 9.14.1P10
  • 9.13.1P13
  • 9.12.1P16
  • 9.10.1P20

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.