ONTAP Hardware KBs
ONTAP Hardware KBs
Featured
Automatic Firmware download Feature
The Automatic Update feature allows ONTAP to automatically download and install recommended firmware
The Automatic Update feature allows ONTAP to automatically download and install recommended firmware
How to perform a health check
A Resolutiom guide of various methods to check the health of your system
A Resolutiom guide of various methods to check the health of your system
Shutdown and Power up procedures
Best practices and procedures to perform a graceful shutdown and power up your ONTAP cluster
Best practices and procedures to perform a graceful shutdown and power up your ONTAP cluster
Controller hardware upgrade Resolution guide
This guide describes how to upgrade controller hardware of an AFF system or a FAS system in a cluster by moving storage or volumes
This guide describes how to upgrade controller hardware of an AFF system or a FAS system in a cluster by moving storage or volumes
Service Processor (SP) & Baseboard Management Controller (BMC) Resolution Guide
Collection of solutions for your SP or BMC questions
Collection of solutions for your SP or BMC questions
DISK FAILED process
Provides guidance around the disk failure process
Provides guidance around the disk failure process
Other Resources
- IPMI.emergency: env_mgr triggers OS halt:One or more temperatuNov, 2026
- Node fails to boot with "BMC IPMI communication failed" errorNov, 2026
- ONTAP AutoSupport SMTP delivery fails due to a faulty internal switchNov, 2026
- Repeated Unknown IPMI completion code error reported when bootingNov, 2026
- How to maximize storage efficiency on All Flash FAS systems running ONTAP 9.xNov, 2026
- Broadcom BES-53248 RCF File Upload Fails with "File transfer failed"Nov, 2026
- After replacing PANIC node, the new node won't boot up and stops at POST with error "IPMI:Get midplane FRU 0 inventory:failed"Nov, 2026
- ONTAP management LIFs unreachable due to physical link or switch misconfigurationNov, 2026
- AFF C30 Controller Unexpected Halt and Sensor Failures Due to Chassis I2C busNov, 2026
- AFF A90 slot1 card information is missing on one node in sysconfig -a and environment statusNov, 2026
- EMS reports "netif.speedNotSupported:error"on the onboard NIC portNov, 2026
- AFF C30 Node Failure in an HA Pair with Loss of Internal Shelf and SP ConnectivityNov, 2026
- System DIMM configuration is not supported by FAS8300Nov, 2026
- SinglePathToDiskShelf_Alert from degraded connectivity due to loose cableNov, 2026
- Takeover disabled due to interconnect downNov, 2026
- NVRAM destage failure predicted for device: NVRAM12 errorsNov, 2026
- How to extract BIOS image file from a service image installation fileNov, 2026
- Intermittent “CHASSIS POWER SUPPLY NEED TO BE REPLACED” and PSU Sensor AnomaliesNov, 2026
- AFF A400, FAS8300, FAS8700: BIOS MRC mapped out DIMM messagesNov, 2026
- Shelf reports enclosure as failedNov, 2026
- How to determine the disk and shelf firmware version on a controller and verify it is up to date
- How to perform graceful shutdown and power up of all ONTAP nodes in a cluster
- BIOS updates for memory reliability and the PPR feature
- How to power up all ONTAP nodes in a cluster following a graceful shutdown
- How to identify a failed disk prior to replacement
- How to manually download EMS log file via SPI?
- Cluster hw_assist: hw_assist functionality is inactive - How to configure hw_assist
Highest rated
(rating)- Is ADP limited to the internal disk on the FAS2720?
- Node reboots with NVDIMM in ERROR condition
- How To Safely Remove Disks from a NetApp System Running ONTAP 9
- Node down due to "ADR event ID: 0" event
- Both nodes in the HA pair of the FAS70 system are displaying as Controller A in sysconfig -a
- Newly installed controller only responsive via BMC prompt due to incorrect line voltage from PDU
- How to collect the log pack on an AFF, ASA, or FAS system running BMC versions 18.X or 19.X
- NVRAM destage failure predicted for device: NVRAM12 errors
- Call home for Health Monitor process nphm: BootmediaFileSystemAlert
- Node perform takeover/giveback automatically due to DIMM UECC error and the DIMM recovers
- boot_recovery procedure does not complete
- How to convert existing 10G or 25G cluster ports to 40G or 100G cluster ports
- How to configure 10G or 25G cluster ports on a new cluster setup
- Can an existing aggregate be expanded with large HDDs after being converted from RAID‑DP to RAID‑TEC
- EMS reports ACP Processor error and SHELF_FAULT error
Recently updated
(date updated)- IPMI.emergency: env_mgr triggers OS halt:One or more temperatu
- Node fails to boot with "BMC IPMI communication failed" error
- ONTAP AutoSupport SMTP delivery fails due to a faulty internal switch
- Repeated Unknown IPMI completion code error reported when booting
- How to maximize storage efficiency on All Flash FAS systems running ONTAP 9.x
- Broadcom BES-53248 RCF File Upload Fails with "File transfer failed"
- After replacing PANIC node, the new node won't boot up and stops at POST with error "IPMI:Get midplane FRU 0 inventory:failed"
- ONTAP management LIFs unreachable due to physical link or switch misconfiguration
- AFF C30 Controller Unexpected Halt and Sensor Failures Due to Chassis I2C bus
- AFF A90 slot1 card information is missing on one node in sysconfig -a and environment status
- EMS reports "netif.speedNotSupported:error"on the onboard NIC port
- AFF C30 Node Failure in an HA Pair with Loss of Internal Shelf and SP Connectivity
- System DIMM configuration is not supported by FAS8300
- SinglePathToDiskShelf_Alert from degraded connectivity due to loose cable
- Takeover disabled due to interconnect down
Recently added
(date created)- Repeated Unknown IPMI completion code error reported when booting
- Broadcom BES-53248 RCF File Upload Fails with "File transfer failed"
- AFF C30 Controller Unexpected Halt and Sensor Failures Due to Chassis I2C bus
- AFF A90 slot1 card information is missing on one node in sysconfig -a and environment status
- ONTAP AutoSupport SMTP delivery fails due to a faulty internal switch
- Intermittent “CHASSIS POWER SUPPLY NEED TO BE REPLACED” and PSU Sensor Anomalies
- What is the expected behavior of NS224 disk shelf firmware update during ONTAP upgrade
- NFS Service Outage Due to NVRAM10 Health Check Panic
- Aggregate Relocation Fails with Disk Inventory Errors
- ONTAP upgrade stuck at waiting for reservations to clear on AFF-C250
- ASA A30 node shuts down due to unreadable NVRAM battery sensors
- Switch interfaces remain down after connecting new nodes to cluster
- Low Battery Cycles and Capacity EMS Alerts on AFF-A700S
- Node unable to boot with Device 2/0/0 (I226 (E0S)) missing message
- AFF C190 Node Down Due to Service Processor SP Failure and Environmental Shutdown