CHASSIS FAN FRU FAILED and INVALID CHASSIS CONFIGURATION
Applies to
- AFF A150
- ONTAP 9
- Cluster-Mode HA Configurations
Issue
- Both Nodes report "CHASSIS FAN FRU FAILED: Multiple fans have failed "at same time :
HA Group Notification from Cluster-01 (CHASSIS FAN FRU FAILED: Multiple fans have failed) ERROR
HA Group Notification from Cluster-02 (CHASSIS FAN FRU FAILED: Multiple fans have failed) ERROR
- EMS errors shows multiple sensors unavailable:
[Cluster: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed
- The following attempts did not resolve the issue, The alert can not be cleared.
- Upgraded BIOS and BMC firmware to latest version ;
- Reboot BMC on both nodes.
- Reseat Motherboard and try to replace Motherboard. Every node can not boot after reseat with following errors even used new MB.
Node A:
+++++++++++++++++++++++++++
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
IPMI:Read midplane FRU common header:timeout
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP recovered successfully after a reset from primary FW image
Waiting for SP ...
IPMI:Read midplane FRU common header:failed
Configuring Devices ...
CPU = 2 Processor(s) Detected.
Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz (CPU 0)
CPUID: 0x00050664. Cores per Processor = 12
CPU1 (CPU 1)
CPUID: 0x00000000. Cores per Processor = 0
32768 MB System RAM Installed.
SATA (AHCI) Device: ATP SATAIII mSATA AF120GSTHI-NT5
Boot Loader version 8.1.0
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: Failed to get FRU data. Abort AUTOBOOT
BMC Event log:
Record 120: Tue Jun 03 14:38:13.347240 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
Record 121: Tue Jun 03 14:39:26.286753 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
Node B:
+++++++++++++++++++++++++++
Starting program at 0xffffffff80348000
---<<BOOT>>---
NetApp Data ONTAP 9.14.1P1
random: registering fast source Intel Secure Key RNG
***************************************************
This platform is not supported in this release.
The system will now halt
***************************************************
BIOS Version: 11.21
Portions Copyright (C) 2014-2023 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
BIOS Version: 11.21
Portions Copyright (C) 2014-2023 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
IPMI:Read midplane FRU common header:timeout
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP recovered successfully after a reset from primary FW image
Waiting for SP ...
IPMI:Read midplane FRU common header:failed
Configuring Devices ...
CPU = 2 Processor(s) Detected.
Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz (CPU 0)
CPUID: 0x00050664. Cores per Processor = 12
CPU1 (CPU 1)
CPUID: 0x00000000. Cores per Processor = 0
32768 MB System RAM Installed.
SATA (AHCI) Device: ATP SATAIII mSATA AF120GSTHI-NT5
Boot Loader version 8.1.0
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: Failed to get FRU data. Abort AUTOBOOT
BMC Event log:
Record 444: Tue Jun 03 14:45:55.696857 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
Record 445: Tue Jun 03 14:47:08.277524 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
4. Conducted cross-controller testing, which revealed the chassis fault.