NoPathToModule_Alert when installing new NS224 shelf
Applies to
- ONTAP 9
- NS224
Issue
- Newly installed NS224 shelf.
- Seeing the following health alert:
cluster::*> system health alert show Node: nodename Alert ID: NoPathToModule_Alert Resource: storage_no-path-to-module_nodename Severity: Major Indication Time: Sat Oct 31 11:36:14 2026 Suppress: true Acknowledge: true Probable Cause: Node "nodename" does not have a path to shelf "2.1" module "A". Possible Effect: Access to the shelf will be lost if the path to the other module fails.Corrective Actions: The node must be cabled to both shelf modules.
- Port is down in the sysconfig -a output for the node called out in the health alert:
slot 1: Dual 100G Ethernet Controller CX6-Mezz e1a MAC Address: d0:39:ea:c2:85:8b (auto-100g_cr4-fd-up) QSFP Vendor: Amphenol QSFP Part Number: 112-00574 QSFP Serial Number: XXXXXXXXXXXXXX e1b MAC Address: d0:39:ea:c2:85:8c (auto-unknown-fd-down) QSFP Vendor: Amphenol QSFP Part Number: 112-00574 QSFP Serial Number: XXXXXXXXXXXXXX Device Type: CX6 PSID(NAP0000000013) Firmware Version: 20.30.1004 Part Number: 111-04588 Hardware Revision: B0 Serial Number: XXXXXXXXXXXX