Skip to main content
NetApp Knowledge Base

BYPASSED disk and ENCLOSURE BYPASSED - Resolution Guide

Views:
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • AFF systems
  • ASA systems
  • FAS systems
  • SAS disk shelves 

Description

This guide identifies the likely cause from the evidence, then sends you to the matching solution article.

A disk bay reports BYPASSED or ENCLOSURE BYPASSED when a shelf module stops presenting the drive on one or both SAS paths.

  • The same status can come from different causes:
    • a failed or poorly seated disk
    • a bay or drawer fault
    • an IOM or SAS-path problem
    • a node-specific discovery state
    • less often a firmware or ONTAP issue
How to identify the error
  1. Collect the following on both nodes, then use the table. A bypass status is evidence, not proof of the failed FRU.

::> system node run -node <node> -command storage show fault -v
::> system node run -node <node> -command sysconfig -a
::> event log show -event *bypass*|*phy.rateunkwn*|*drivephy*

Example:

::> system node run -node <node> -command storage show fault -v

Enclosure Status: critical
Channel: 1a
Shelf: 2
Shelf Type: DS460-12
Module Type: IOM12B

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
 51 [Bay  3]: OK                01,03,00,00
 52 [Bay  4]: CRITICAL          02,04,00,0C   BYPASSED B, BYPASSED A
 53 [Bay  5]: OK                01,05,00,00

::> storage shelf show


                                                       Module
       Shelf Name Shelf ID Serial Number   Model       Type   Status
----------------- -------- -------------------------- ------ -----------       1.10       10 ABCDE12345678       DS460-12    IOM12B Critical

  1. Note the following, then use the table below:
    1. Scope — one bay vs several bays vs the whole shelf
    2. PathBYPASSED A only, BYPASSED B only, or both
    3. Visibility — whether the disk still appears in sysconfig -a / storage disk show
    4. Node comparison — both nodes see the same fault, or only one node
    5. Shelf type — DS460C (DS460-12) or another SAS shelf
    6. Recent change — disk replace, IOM reseat, shelf firmware, or ONTAP upgrade

    Sign in to view the entire content of this KB article.

    New to NetApp?

    Learn more about our award-winning Support

    NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.