BYPASSED disk and ENCLOSURE BYPASSED - Resolution Guide
Applies to
- ONTAP 9
- AFF systems
- ASA systems
- FAS systems
- SAS disk shelves
Description
This guide identifies the likely cause from the evidence, then sends you to the matching solution article.
A disk bay reports BYPASSED or ENCLOSURE BYPASSED when a shelf module stops presenting the drive on one or both SAS paths.
- The same status can come from different causes:
- a failed or poorly seated disk
- a bay or drawer fault
- an IOM or SAS-path problem
- a node-specific discovery state
- less often a firmware or ONTAP issue
How to identify the error
Collect the following on both nodes, then use the table. A bypass status is evidence, not proof of the failed FRU.
::> system node run -node <node> -command storage show fault -v::> system node run -node <node> -command sysconfig -a::> event log show -event *bypass*|*phy.rateunkwn*|*drivephy*
Example:
::> system node run -node <node> -command storage show fault -v
Enclosure Status: criticalChannel: 1aShelf: 2Shelf Type: DS460-12Module Type: IOM12B
Disk Elements:Element Status Status Bytes Status Descriptions 51 [Bay 3]: OK 01,03,00,00 52 [Bay 4]: CRITICAL 02,04,00,0C BYPASSED B, BYPASSED A 53 [Bay 5]: OK 01,05,00,00
::> storage shelf show
Module Shelf Name Shelf ID Serial Number Model Type Status----------------- -------- -------------------------- ------ ----------- 1.10 10 ABCDE12345678 DS460-12 IOM12B Critical
- Note the following, then use the table below:
- Scope — one bay vs several bays vs the whole shelf
- Path —
BYPASSED Aonly,BYPASSED Bonly, or both - Visibility — whether the disk still appears in
sysconfig -a/storage disk show - Node comparison — both nodes see the same fault, or only one node
- Shelf type — DS460C (
DS460-12) or another SAS shelf - Recent change — disk replace, IOM reseat, shelf firmware, or ONTAP upgrade