FAS8200

Issue

  • The fault LEDs on the front and back of the storage are all on.
  • The following messages can be observed on the system.
[?]  Thu Oct 17 13:18:58 +0900 [Node-02: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.
  • P3V3_BATT shows nc in SP-LATEST-IPMI.
P3V3_BATT        | 0.032      | Volts      | nc         | 0.016     | 0.032     | 4.048     | 4.064
  • Lower Non-critical going low occurs repeatedly in SP-LATEST-SYSTEM-EVENT-LOG
Record 976: Tue Oct 15 21:57:06 2024 [IPMI.notice]: 0002 | 02 | EVT: 01500202 | P3V3_BATT | Assertion Event, "Lower Non-critical going low "
Record 977: Tue Oct 15 21:57:48 2024 [IPMI.notice]: 0102 | 02 | EVT: 81500402 | P3V3_BATT | Deassertion Event, "Lower Non-critical going low "
Record 978: Tue Oct 15 21:59:41 2024 [IPMI.notice]: 0202 | 02 | EVT: 01500202 | P3V3_BATT | Assertion Event, "Lower Non-critical going low "
Record 979: Tue Oct 15 22:01:12 2024 [IPMI.notice]: 0302 | 02 | EVT: 81500402 | P3V3_BATT | Deassertion Event, "Lower Non-critical going low "
……
Record 1472: Wed Oct 16 20:04:05 2024 [IPMI.notice]: f003 | 02 | EVT: 01520101 | P3V3_BATT | Assertion Event, "Lower Critical going low "
Record 1473: Wed Oct 16 20:04:19 2024 [IPMI.notice]: f103 | 02 | EVT: 81520301 | P3V3_BATT | Deassertion Event, "Lower Critical going low "
  • The error event below shows in System Manger.
Real-time clock battery is dangerously low.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.