IOM12B missing after a scheduled power maintenance
Applies to
- DS460C
- IOM12B
Issue
During a power maintenance exercise on site, the system was gracefully shut down. The entire rack was powered down by switching off the feeds to the rack PDUs. Upon powering the systems back on, a health check revealed that the shelf had only a single path to both controllers.
- The bottom IOM module on DS460C had no LEDs on.
- After flipping the PSU switch, the LEDs on the IOM module were restored.
- After 2-3 minutes, the cluster performs a takeover
::> system health alert show
Node: node01
Resource: Shelf 1.10
Severity: Major
Indication Time: Thu Aug 08 15:47:22 2024
Suppress: false
Acknowledge: false
Probable Cause: Controller node01 has only a single-path
configuration to disk shelf 1.10. This might occur
when the controller does not have dual-path
configuration to stack 1, a SAS HBA port on the
controller connected to the disk shelf is disabled, or
shelf-to-shelf cabling is incorrect.
Possible Effect: Access to disk shelf 1.10 via controller node01
might be lost with a failure of controller 3a port, a
single shelf-to-shelf cable or a single disk shelf IOM.
Corrective Actions: 1. Consult the guide applicable to your IOM12B disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect controller node01 to the first and last disk shelf of stack 1 using active SAS HBA ports.
3. Verify that controller node01 is cabled to IOM A at one end and IOM B at another end of stack 1.
4. If disk shelf 1.10 is located between two disk shelves within stack 1, verify that IOM A and IOM B are properly cabled to their
independent domains.
5. Contact technical support if the alert persists.
- Sysconfig -a shows blank for IOM12B module B
Shelf 10: DS460-12 Firmware rev. IOM12B A: 0141 B: ----