After a controller (motherboard) replacement in an HA pair, the replacement node owns no disks and waits for giveback. This is expected. If one read of the partner's state over the HA interconnect times out during that wait, the node exits the wait and reboots, because it has no local disks to continue. The node can repeat this cycle until the disks are reassigned manually.
Console messages seen during this condition:
  • HA interconnect: OFW transfer timed out.
  • fm_run0: No disks found & can't find partner's state.

  • WARNING: there do not appear to be any disks attached to the system.

  •  
    No root volume found.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.