Health Monitor SPAutoUpgradeFailedMajorAlert SP upgrade fails - AutoSupport Message
Applies to
- Upgrade
- ONTAP 9
- AFF systems
- FAS systems
- SP (Service Processor)
- BMC (Baseboard Management Controller)
- hm.alert.raised:alert
- SPAutoUpgradeFailedMajorAlert
Event Summary
A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package.
Validate
::> system health status show
Status
---------------
degraded
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor degraded
Switch-Health ok
::> system health alert show
Node | cluster1-01 |
---|---|
Monitor | controller |
Alert ID | SPAutoUpgradeFailedMajorAlert |
Alerting Resource | SP Upgrade |
Subsystem | Service-Processor |
Perceived Severity | Major |
Probable Cause | Configuration_error |
Description | A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. |
Corrective Actions |
|
Possible Effect | Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package. |
Resolution
- Verify if an upgrade is currently in progress:
::> service-processor image update-progress show
Workaround
- Attempt to manually update the FW from the SP / BMC prompt directly
- Follow the steps to update ONTAP's Service Processor (SP) or Baseboard Management Controller (BMC)
- Select option Service Processor image for installation from the SP prompt
- Follow the Installation Instructions & Notes