AutoSupport Message: Health Monitor SPAutoUpgradeFailedMajorAlert - SP upgrade fails
Applies to
Clustered Data ONTAP
Issue
After a Data ONTAP upgrade the cluster displays the following health monitor alert and the system health status is degraded.
Node | cluster1-01 |
Monitor | controller |
Alert ID | SPAutoUpgradeFailedMajorAlert |
Alerting Resource | SP Upgrade |
Subsystem | Service-Processor |
Perceived Severity | Major |
Probable Cause | Configuration_error |
Description | A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. |
Corrective Actions |
|
Possible Effect | Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package. |
Policy | SPAutoUpgradeFailedMajorAlertPolicy |
Additional Information |
New firmware available: true New firmware Version: 3.1.2P1 Auto update: true Auto update Status: installed Previous AutoUpdate Status: failed |
Alerting Resource Name | SP Upgrade |
Additional Alert Tags | device |
::> system health status show
Status
---------------
degraded
::> service-processor image show
Is
Node Type Image Status Current Version
---------------- ----- ------- ----------- ------- --------
cluster1-01 SP
primary installed true 3.0.2
backup installed false 3.0.1P1
cluster1-02 SP
primary installed true 3.0.2
backup installed false 3.0.1P1
4 entries were displayed.