SolidFire Hardware
SolidFire Hardware
Featured
Unresponsive BMC
Troubleshooting unresponsive BMC on H610S
Troubleshooting unresponsive BMC on H610S
BMC Self Test
BMC Self Test failed
BMC Self Test failed
SensorReadingFailed
SensorReadingFailed': IPMI diagnostics are currently unresponsive
SensorReadingFailed': IPMI diagnostics are currently unresponsive
Input Missing or Out of Range
Power supply PSx input missing or out of range
Power supply PSx input missing or out of range
DriveAvailableWarning
DriveAvailable Warning AutoSupport Message
DriveAvailable Warning AutoSupport Message
Other Resources
- Metadrive frequently goes to available state due to malfunction fan in NVRAMWed, 20 Sep 2023
- Network interface eth<x> is down or cable is unplugged due to faulty SFP CableWed, 13 Sep 2023
- Rebranding of H700S nodes to H410SMon, 11 Sep 2023
- Nmap scan of H610S reports a vulnerability specific to Diffie-Hellman groups with insufficient key strengthFri, 08 Sep 2023
- Node Reporting Warning Predictive Failure EventsFri, 01 Sep 2023
- Unable to power ON the SolidFire storage node after an unplanned node offlineThu, 31 Aug 2023
- SolidFire node offline event caused by hardware voltage issueMon, 28 Aug 2023
- Active IQ reports networkEvent : rx_length_errorsWed, 02 Aug 2023
- driveFailed on Element clusterSat, 08 Jul 2023
- HCC Storage Firmware Upgrade Fails When Connection To Storage Node BMC Is LostFri, 07 Jul 2023
- Node Network Ports Not Functioning ProperlyThu, 06 Jul 2023
- Critical Sensors "Volt_PVCCIN_CPU1" and "Thermal trip" on BMC consoleThu, 06 Jul 2023
- Node Offline due to failing NVRAM card with 'hung_task' and 'hung_task_timeout_secs'Tue, 04 Jul 2023
- Compute node details not showing in HCI after scale process failureTue, 27 Jun 2023
- Drive Slot LED blinking amber on H610S without any alerts or events in cluster UITue, 27 Jun 2023
- RTFI is in stuck due to [UnhandledError pid=1 cmd=sfnvdimm arm ${nvid}]Mon, 19 Jun 2023
- Storage Node Reports Error Drive Failed xDrive(s) With State: NodeOfflineFri, 09 Jun 2023
- Self resolved "Power supply PSx is failed" alerts occur every few daysWed, 31 May 2023
- incorrectBondPortCount and volumesDegraded alerts due to bond10G issueWed, 24 May 2023
- No boot device error causing Master Service to be unresponsiveTue, 02 May 2023
- ExcessiveCapacitorVoltage alert on NetApp Element storage nodesFri, 29 Sep 2023
- Network interface eth<x> is down or cable is unplugged due to faulty SFP CableSun, 24 Sep 2023
- Persistent blockClusterFull alerts on Element storage clusterThu, 21 Sep 2023
- How to configure SNMP for SolidFire storage systemThu, 21 Sep 2023
- Metadrive frequently goes to available state due to malfunction fan in NVRAMWed, 20 Sep 2023
- "sensorReadingFailed" and "ensembleDegraded" alerts are detectedWed, 20 Sep 2023
- QoSSIOC status shows server errorSun, 17 Sep 2023
- How to replace a SolidFire or HCI Storage nodeThu, 14 Sep 2023
- AutoSupport Message: Power supply PSx input missing or out of rangeThu, 14 Sep 2023
- Replicating volume pairs stopped due to there is no target volumeThu, 14 Sep 2023
- SolidFire node offline event caused by hardware voltage issueThu, 14 Sep 2023
- How to clear the amber blinking lights on ElementWed, 13 Sep 2023
- Rebranding of H700S nodes to H410SMon, 11 Sep 2023
- Nmap scan of H610S reports a vulnerability specific to Diffie-Hellman groups with insufficient key strengthFri, 08 Sep 2023
- Power supply shows "Config Error/Redundancy Lost" on IPMI event after BMC cold resetThu, 07 Sep 2023
- Node Reporting Warning Predictive Failure EventsFri, 01 Sep 2023
- Unable to power ON the SolidFire storage node after an unplanned node offlineThu, 31 Aug 2023
- How to recover from setup-mnode failuresThu, 31 Aug 2023
- BMC UI not respondingThu, 31 Aug 2023
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element softwareWed, 23 Aug 2023