Why did my SP/BMC reboot during a FW upgrade?
Applies to
- All Platforms
- ASA systems
- AFF systems
- FAS systems
Answer
After the SP/BMC update is complete, the SP/BMC is automatically rebooted.
- ONTAP will inform you prior to rebooting the SP/BMC.
Firmware update will need to reboot the SP on completion. If your console connection is through the SP, it will be disconnected.
- To display the SP/BMC update status, including whether an update is in progress, the update start and end time, and the completion percentage:
system service-processor image update-progress show -node node_name
Node: node_name
Latest SP Firmware Update Start Timestamp: 7/18/2017 12:22:37
Latest SP Firmware Update Percentage Done: 100
Latest SP Firmware Update End Timestamp: 7/18/2017 12:28:14
Is Update in Progress: no
- To verify that the SP/BMC is online and running the intended version, run:
system service-processor show -node node_name
Additional Information
- This is covered here as well DownloadsSystem Firmware & Diagnostics Firmware
- The download page will provide the steps to update your SP/BMC