Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 57 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/False_SwitchFanNotPresent_Alert_alert_is_reported_by_Health_Monitor
      Applies to ONTAP 9 Issue Despite no issues seen on cluster switches, following AutoSupport alert messages are received: Call home for Health Monitor process cshm: SwitchFanNotPresent_Alert
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Node_reports_StorageFCAdapterFault_Alert_for_down_or_unused_FC_ports
      FC ports in initiator mode The node sends AutoSupport alerts for StorageFCAdapterFault for down FC ports after every reboot. The reported port is not in use. The Metrocluster_Node subsystem health get...FC ports in initiator mode The node sends AutoSupport alerts for StorageFCAdapterFault for down FC ports after every reboot. The reported port is not in use. The Metrocluster_Node subsystem health gets degraded: cluster::> system health subsystem show Probable Cause: FC initiator adapter 4d is at fault. Ensure that the FC initiator link has not been tampered with. Verify the operational status of the FC initiator adapter by using the command "system node run -node
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/New_Cisco_Nexus_9336C-FX2_cluster_switch_is_unsupported
      Applies to Cisco 9336C-FX2 ONTAP 9.1 - 9.4 ONTAP 9.5P1 - 9.5P15 ONTAP 9.6P1 - 9.6P11 ONTAP 9.7P1 - 9.7P9 Issue Cisco Nexus 9336C-FX2 showing as unsupported: HA Group Notification (Health Monitor proce...Applies to Cisco 9336C-FX2 ONTAP 9.1 - 9.4 ONTAP 9.5P1 - 9.5P15 ONTAP 9.6P1 - 9.6P11 ONTAP 9.7P1 - 9.7P9 Issue Cisco Nexus 9336C-FX2 showing as unsupported: HA Group Notification (Health Monitor process cshm: UnsupportedSwitch_Alert[Switch_Name]) ALERT CSHM-SWITCH-CONFIG.XML autosupport shows the switches as Unsupported Model System health alert for Unsupported cluster switch is detected
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/disk_shelf_reporting_as_Critical_due_to_a_loose_power_cable
      Critical fault and PSU error are reported against a newly installed shelf. DS460-12 (S/N xxxxxxxxx) shelf 10 on channel 0b power error for Power supply 1: critical status; AC Fail. This module is on t...Critical fault and PSU error are reported against a newly installed shelf. DS460-12 (S/N xxxxxxxxx) shelf 10 on channel 0b power error for Power supply 1: critical status; AC Fail. This module is on the rear of the shelf at the top middle. [ClusterA: dsa_worker4: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED Shelf: 10 Shelf Type: DS460-12 Power Supplies: 1: CRITICAL 02,00,00,F3 DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL Element Status Status Bytes Status Descriptions
    • https://kb.netapp.com/on-prem/E-Series/Management-Apps-KBs/How_to_identify_which_disk_on_a_FAS_FlexArray_maps_to_a_corresponding_E_series_volume
      Applies to • E-series • FlexArray • V-series • FAS Description Some FlexArray setups will have virtual disks which are being presented from a backend storage. The E-series system will present each vol...Applies to • E-series • FlexArray • V-series • FAS Description Some FlexArray setups will have virtual disks which are being presented from a backend storage. The E-series system will present each volume to the FAS system as a disk. In the event troubleshooting is needed against a specific FAS disk and which volume on E-series it corresponds to.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Health_monitor_MixOfIOMAandIOMBConnection_Alert
      Applies to AFF and FAS systems Issue Health monitor raised an alert with Alert Id = 'MixOfIOMAandIOMBConnection_Alert' Example: Mon May 18 17:11:29 CEST [NETAPP-01: nchmd: hm.alert.raised:alert]: Aler...Applies to AFF and FAS systems Issue Health monitor raised an alert with Alert Id = 'MixOfIOMAandIOMBConnection_Alert' Example: Mon May 18 17:11:29 CEST [NETAPP-01: nchmd: hm.alert.raised:alert]: Alert Id = MixOfIOMAandIOMBConnection_Alert , Alerting Resource = 265470534849464912:3 raised by monitor node-connect
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_determine_if_an_AFF_or_FAS_model_supports_an_external_USB_device
      Applies to ONTAP 9 AFF A700, AFF A700s, AFF A300, AFF A200 and later models FAS9000, FAS8200, FAS2650, FAS2620 and later models Description Most AFF and FAS hardware models have one or more USB Type A...Applies to ONTAP 9 AFF A700, AFF A700s, AFF A300, AFF A200 and later models FAS9000, FAS8200, FAS2650, FAS2620 and later models Description Most AFF and FAS hardware models have one or more USB Type A ports. However, not all models support use of that port for external USB devices for use with activities such as boot_recovery or coredump saving. This support was added with AFF and FAS models introduced with ONTAP 9.1.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/How_to_reboot_a_cluster_interconnect_switch
      Applies to ONTAP Cluster interconnect switches NetApp CN1610 Broadcom BES-53248 Cisco Nexus 3132Q-V Cisco Nexus 3232C Cisco Nexus 5596 Cisco Nexus 92300YC Cisco Nexus N9K-C9336C-FX2 Description How to...Applies to ONTAP Cluster interconnect switches NetApp CN1610 Broadcom BES-53248 Cisco Nexus 3132Q-V Cisco Nexus 3232C Cisco Nexus 5596 Cisco Nexus 92300YC Cisco Nexus N9K-C9336C-FX2 Description How to reboot a cluster interconnect switch.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/SwitchFanNotPresent_Alert_reported_by_CSHM_for_Cisco_cluster_network_switches
      “SwitchFanNotPresent_Alert” is reported by CSHM for one or more fan modules of the cluster network switch: The cluster switch health monitor (CSHM) can only detect that a fan or a power supply is miss...“SwitchFanNotPresent_Alert” is reported by CSHM for one or more fan modules of the cluster network switch: The cluster switch health monitor (CSHM) can only detect that a fan or a power supply is missing when the queries to the switch fail to return information about all the fans or power supplies. Login to both the cluster switches and verify if all the fan modules are operating in good condition, by running the following command:
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/VSS_Backups_failing_with_error_message_Failed_to_create_VSS_snapshot
      Applies to Ontap 9.x FAS Systems Issue VSS backups are failing when snapshot creation takes more than 10 seconds VSS will freeze IO operations in order to take a consistent snapshot In EMS logs the fo...Applies to Ontap 9.x FAS Systems Issue VSS backups are failing when snapshot creation takes more than 10 seconds VSS will freeze IO operations in order to take a consistent snapshot In EMS logs the following errors are shown: Activity [Creating Backup] failed with error: Failed to create VSS snapshot [Error Code: -2147212524] [VSS_E_HOLD_WRITES_TIMEOUT] [Error Code: -2147212524] [VSS_E_HOLD_WRITES_TIMEOUT]
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_reports_NVRAM_battery_power_fault_while_booting
      KB provides solution when Node reports NVRAM battery power fault while booting in FAS and AFF.