Applies to StorageGRID 11.7.0.4 SG6060 StorageGRID appliance BMC Issue When attempting to apply an SSL certificate for BMC on a GRID appliance an error is given "Error while uploading certificate".
Applies to NetApp Hybrid Cloud Control NetApp Element software Issue On NetApp Hybrid Cloud Control: Node failed one or more health checks. Expand this row to view details When expanding the row, the ...Applies to NetApp Hybrid Cloud Control NetApp Element software Issue On NetApp Hybrid Cloud Control: Node failed one or more health checks. Expand this row to view details When expanding the row, the following descriptions appear: Is there correct mapping between ESXi host and hardware host(BMC)?
Applies to AFF A220 FAS2750 FAS2720 Issue Host detects duplicate IP address conflicts from SP MAC address The duplicate IP addresses are 10.1.1.4 and 10.1.1.5 The Baseboard Management Controller (BMC)...Applies to AFF A220 FAS2750 FAS2720 Issue Host detects duplicate IP address conflicts from SP MAC address The duplicate IP addresses are 10.1.1.4 and 10.1.1.5 The Baseboard Management Controller (BMC) firmware is on fixed releases for bug 1217916
Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) ha...Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) has not been cleared, the warning LEDs will remain activated. This article will describe how to clear the SEL from BMC/IPMI. Note: Not all LED errors can be resolved by clearing the SEL. Refer Additional Information for further steps/investigation that may be required.
An AFF A800 can trigger an Environmental Shutdown due to a critical temperature issue in the "LED_Board_Temp1" Record 1890: Sun Dec 01 23:34:31.610000 2019 [IPMI.notice]: 0034 | 02 | EVT: 01592d2d | L...An AFF A800 can trigger an Environmental Shutdown due to a critical temperature issue in the "LED_Board_Temp1" Record 1890: Sun Dec 01 23:34:31.610000 2019 [IPMI.notice]: 0034 | 02 | EVT: 01592d2d | LED_Board_Temp1 | Assertion Event, "Upper Critical going high" | Reading: 45.000 | Threshold: 45.000 Record 1891: Sun Dec 01 23:34:34.640000 2019 [IPMI.notice]: 0035 | 02 | EVT: 8159182d | LED_Board_Temp1 | Deassertion Event, "Upper Critical going high" | Reading: 24.000 | Threshold: 45.000
Applies to StorageGRID SG6000 Appliances StorageGRID SG1000 Appliances Description This article describes how to configure a network on the BMC (Baseboard Management Controller) for the SG6000 and SG1...Applies to StorageGRID SG6000 Appliances StorageGRID SG1000 Appliances Description This article describes how to configure a network on the BMC (Baseboard Management Controller) for the SG6000 and SG1000 appliances.
Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC We...Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC Web GUI How to disable BMC IPMItool access How to disable BMC SSH access
Applies to AFF-A800 Issue Following BMC upgrade, EMS logs showing alert spsm_listener: sp.firmware.upgrade.reqd:alert]: The SP firmware 10.X is incompatible with Data ONTAP for SwitchAPI.