    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/SSH_connection_refused_to_SP_or_BMC_after_newly_introduced_controller
      If connected to the serial console of the controller at the same time of the SSH attempt, similar errors to the following will be seen in the output:
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/An_AFF_A800_can_trigger_an_Environmental_Shutdown_due_to_a_critical_temperature_issue_in_the_LED_Board_Temp1_sensor
      An AFF A800 can trigger an Environmental Shutdown due to a critical temperature issue in the "LED_Board_Temp1" Record 1890: Sun Dec 01 23:34:31.610000 2019 [IPMI.notice]: 0034 | 02 | EVT: 01592d2d | L...An AFF A800 can trigger an Environmental Shutdown due to a critical temperature issue in the "LED_Board_Temp1" Record 1890: Sun Dec 01 23:34:31.610000 2019 [IPMI.notice]: 0034 | 02 | EVT: 01592d2d | LED_Board_Temp1 | Assertion Event, "Upper Critical going high" | Reading: 45.000 | Threshold: 45.000 Record 1891: Sun Dec 01 23:34:34.640000 2019 [IPMI.notice]: 0035 | 02 | EVT: 8159182d | LED_Board_Temp1 | Deassertion Event, "Upper Critical going high" | Reading: 24.000 | Threshold: 45.000
    • https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/How_to_login_to_E_Series_BMC_on_EF600_EF300
      Applies to EF600 EF300 Description Process to login via the shell to the BMC (Baseboard Management Controller) on a EF600 / EF300
    • https://kb.netapp.com/hybrid/StorageGRID/Platforms/Unable_to_upload_CA_signed_Certificate_to_StorageGRID_SG6060_BMC_though_is_in_.pem_x509_format
      Applies to StorageGRID 11.7.0.4 SG6060 StorageGRID appliance BMC Issue When attempting to apply an SSL certificate for BMC on a GRID appliance an error is given "Error while uploading certificate".
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/BMC_SSH_fails_with_Connection_refused_on_FAS8300_AFF_A400_AFF_A800_and_FAS8700
      Connection refused on FAS8300, AFF-A400 and FAS8700 when attempting to SSH to the BMC, as there might be an issue with the BMC configuration file.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Hybrid_Cloud_Control_compute_health_check_fails_with_BMC_errors
      Applies to NetApp Hybrid Cloud Control NetApp Element software Issue On NetApp Hybrid Cloud Control: Node failed one or more health checks. Expand this row to view details When expanding the row, the ...Applies to NetApp Hybrid Cloud Control NetApp Element software Issue On NetApp Hybrid Cloud Control: Node failed one or more health checks. Expand this row to view details When expanding the row, the following descriptions appear: Is there correct mapping between ESXi host and hardware host(BMC)?
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_clear_the_amber_blinking_lights_on_Element
      Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) ha...Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) has not been cleared, the warning LEDs will remain activated. This article will describe how to clear the SEL from BMC/IPMI. Note: Not all LED errors can be resolved by clearing the SEL. Refer Additional Information for further steps/investigation that may be required.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Host_detects_duplicate_IP_address_conflicts_from_Service_Processor_SP_MAC_address
      Applies to AFF A220 FAS2750 FAS2720 Issue Host detects duplicate IP address conflicts from SP MAC address The duplicate IP addresses are 10.1.1.4 and 10.1.1.5 The Baseboard Management Controller (BMC)...Applies to AFF A220 FAS2750 FAS2720 Issue Host detects duplicate IP address conflicts from SP MAC address The duplicate IP addresses are 10.1.1.4 and 10.1.1.5 The Baseboard Management Controller (BMC) firmware is on fixed releases for bug 1217916
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/HCC_failed_to_connect_to_BMC
      Applies to NetApp HCI NetApp Hybrid Cloud Control 2.15.28 Issue When attempting to connect to BMC from HCC an error is displayed about incorrect credentials
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/BMC_SP_firmware_unknown_Not_able_to_set_the_IP_address_of_BMC
      Applies to AFF-A220 FAS2720 FAS2750 FAS8200 ONTAP 9.x Issue Firmware Version 'Unknown Not able to update the firmware or set IP on BMC or SP In sysconfig -a, the only out you see for the Service Proce...Applies to AFF-A220 FAS2720 FAS2750 FAS8200 ONTAP 9.x Issue Firmware Version 'Unknown Not able to update the firmware or set IP on BMC or SP In sysconfig -a, the only out you see for the Service Processor. Service Processor Status: Online
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Rebooting_BMC_Stopping_IPMI_Stack__IPMIMainkillall__can_t_kill_pid_1121__Operation_not_permitted_after_BMC_firmware_update
      Applies to BMC 11.4, 11.6 firmware update to BMC 11.4 and 11.6 FAS2750 / FAS2720 / AFF A220 Issue Message when upgrading BMC firmware from 11.3P2 to 11.4: Rebooting BMC...Stopping IPMI Stack: IPMIMain...Applies to BMC 11.4, 11.6 firmware update to BMC 11.4 and 11.6 FAS2750 / FAS2720 / AFF A220 Issue Message when upgrading BMC firmware from 11.3P2 to 11.4: Rebooting BMC...Stopping IPMI Stack: IPMIMainkillall: can't kill pid 1121: Operation not permitted Stopping IPMI Stack: IPMIMainkillall: can't kill pid 1122: Operation not permitted