Skip to main content
NetApp Knowledge Base

HOST_PORT_FAIL - Disabled by IOM - Autosupport message

Views:
3,565
Visibility:
Public
Votes:
2
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • callhome.hostport.disable:error
  • Call home for HOST_PORT_FAIL - Disabled by IOM

Event Summary

This message occurs when an I/O Module (IOM) disables a host port for a drive due to excessive errors on the port.

Validate

AutoSupport Message

HA Group Notification from Node Name (HOST_PORT_FAIL - Disabled by IOM) WARNING

EMS Log

event log show -severity * -message-name callhome*

[Node Name: dsa_worker3: callhome.hostport.disable:error]: Call home for HOST_PORT_FAIL - Disabled by IOM

event log show -severity * -event *sas.*    (Example output)

[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 40', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 came back.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'DISCOVERY: REPORT GENERAL on expander 5:00a098:0075d9d:3f: Configing 2 -- continuing (0)', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 40', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'DISCOVERY: REPORT GENERAL on expander 5:00a098:0075d9d:3f: Configing 2 -- continuing (1)', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 came back.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 10', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: dsa_worker5: ds.sas.running.disparity:debug]: [  9 ] on channels 0b shelf ID 2 IOM A9 reports running disparity errors.
[Node Name: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidated.', 'adapterName': '0a'}
[Node Name: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Invalidating device 0a.02.9. ', 'adapterName': '0a'}
[Node Name: dsa_worker1: ds.sas.running.disparity:debug]: [  9 ] on channels 0a shelf ID 2 IOM B9 reports running disparity errors.
[Node Name: dsa_worker1: ds.sas.hostphy.disableErr:critical]: [  9 ] on channels 0a shelf id 2 IOM BDisabled due to excessive phy changes.

Command line

system node run -node <NodeName> -command sasadmin expander_phy_state

Expander phy state on 0a.2 (NETAPP  :DS424IOM6        SHJHU1450000273):
                              Pwr         Invald Disprt Loss   Phy    CRC    Phy                    
                          Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA            
PHY/BAY STATE             ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt    Cnt    Affiliation     
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      3      ----------------
1/P0:1 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      3      ----------------
2/P0:2 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      3      ----------------
3/P0:3 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      3      ----------------
4/P1:0 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      1      ----------------
5/P1:1 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      1      ----------------
6/P1:2 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      1      ----------------
7/P1:3 6.0 Gb/s          --- --- --- --- 0      0      0      0      0      1      ----------------
8/0    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
9/1    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
10/2    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
11/3    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
12/4    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
13/5    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
14/6    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
15/7    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
16/8    6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
17/9    Disabled/BRST_PCD YES 0   0   0  
18/10   6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
19/11   6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------
20/12   6.0 Gb/s          YES 0   0   0   0      0      0      0      0      2      ----------------

Resolution

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.