HOST_PORT_FAIL - Disabled by IOM - Autosupport message
Applies to
- ONTAP 9
- callhome.hostport.disable:error
Call home for HOST_PORT_FAIL - Disabled by IOM
Event Summary
This message occurs when an I/O Module (IOM) disables a host port for a drive due to excessive errors on the port.
Validate
AutoSupport Message
HA Group Notification from Node Name (HOST_PORT_FAIL - Disabled by IOM) WARNING
EMS Log
event log show -severity * -message-name callhome*
[Node Name: dsa_worker3: callhome.hostport.disable:error]: Call home for HOST_PORT_FAIL - Disabled by IOM
event log show -severity * -event *sas.*
(Example output)
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 40', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 came back.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'DISCOVERY: REPORT GENERAL on expander 5:00a098:0075d9d:3f: Configing 2 -- continuing (0)', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 40', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'DISCOVERY: REPORT GENERAL on expander 5:00a098:0075d9d:3f: Configing 2 -- continuing (1)', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 came back.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidate debounce - 10', 'adapterName': '0a'}
[Node Name: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Asyncd device scan done.', 'adapterName': '0a'}
[Node Name: dsa_worker5: ds.sas.running.disparity:debug]: [ 9 ] on channels 0b shelf ID 2 IOM A9 reports running disparity errors.
[Node Name: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0a.02.9 invalidated.', 'adapterName': '0a'}
[Node Name: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Invalidating device 0a.02.9. ', 'adapterName': '0a'}
[Node Name: dsa_worker1: ds.sas.running.disparity:debug]: [ 9 ] on channels 0a shelf ID 2 IOM B9 reports running disparity errors.
[Node Name: dsa_worker1: ds.sas.hostphy.disableErr:critical]: [ 9 ] on channels 0a shelf id 2 IOM BDisabled due to excessive phy changes.
Command line
system node run -node <NodeName> -command sasadmin expander_phy_state
Expander phy state on 0a.2 (NETAPP :DS424IOM6 SHJHU1450000273):
Pwr Invald Disprt Loss Phy CRC Phy
Pwr Ccl Rsv Rls DWord Error Sync Reset Error Change SATA
PHY/BAY STATE ON Cnt Cnt Cnt Count Count Count Prob Cnt Cnt Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 6.0 Gb/s --- --- --- --- 0 0 0 0 0 3 ----------------
1/P0:1 6.0 Gb/s --- --- --- --- 0 0 0 0 0 3 ----------------
2/P0:2 6.0 Gb/s --- --- --- --- 0 0 0 0 0 3 ----------------
3/P0:3 6.0 Gb/s --- --- --- --- 0 0 0 0 0 3 ----------------
4/P1:0 6.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
5/P1:1 6.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
6/P1:2 6.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
7/P1:3 6.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
8/0 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
9/1 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
10/2 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
11/3 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
12/4 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
13/5 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
14/6 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
15/7 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
16/8 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
17/9 Disabled/BRST_PCD YES 0 0 0
18/10 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
19/11 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
20/12 6.0 Gb/s YES 0 0 0 0 0 0 0 0 2 ----------------
Resolution
- Check the status of a Part Request or Field Support Order
- Track Part Request (PREQ) shipments
- Replace the failed drived