Search
- Filter results by:
- View attachments
- https://kb.netapp.com/Legacy/ONTAP/7Mode/AutoSupport_message__Exceeded_maximum_raw_capacity_CRITICAL[filer11: raid.disk.tooBig.all.reminder:error]: System raw capacity XXX TB exceeds the XXX TB maximum. Reverting to a Data ONTAP release with a lower maximum capacity causes a panic. When reverting to...[filer11: raid.disk.tooBig.all.reminder:error]: System raw capacity XXX TB exceeds the XXX TB maximum. Reverting to a Data ONTAP release with a lower maximum capacity causes a panic. When reverting to a Data ONTAP release with a lower maximum capacity than the capacity supported by the newer version of Data ONTAP, without removing the added capacity, the filer may panic. Reverting to a Data ONTAP release with a lower maximum capacity.
- https://kb.netapp.com/Legacy/ONTAP/7Mode/AutoSupport_Message__Chassis_Power_DegradedKB article is for AutoSupport Message: Chassis Power Degraded. This message is sent when there are issues with the power supply.
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Ensemble_EventApplies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Ensemble Event Ensemble degraded This alert type Ensemble Event corresponds to the failur...Applies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Ensemble Event Ensemble degraded This alert type Ensemble Event corresponds to the failure in Active IQ - Reporting -> Events. While the alert type Ensemble degraded corresponds to the failure in Active IQ - Error Log.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Weekly_ASUP_fails___duplicate_payload_body_filenameApplies to ONTAP 9 Issue Sending Autosupport fails with an error. : asup asup_create_manifest failed (ASUP xx): The AutoSupport generation failed due to a duplicate payload body filename( ))
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Schedule_action_failed_for_schedule_IDsApplies to NetApp Element software NetApp SolidFire NetApp HCI Issue Alert seen in NetApp Active IQ: Schedule action failed for schedule IDs: [X]
- https://kb.netapp.com/Legacy/NetApp_HCI/OS/AutoSupport_Message__Host_connection_and_power_stateKB is for the AutoSupport Message 'Host connection and power state'. It provides the solution when VMware alarm in NetApp SolidFire Active IQ is Alert Name: Host connection and power state and Descrip...KB is for the AutoSupport Message 'Host connection and power state'. It provides the solution when VMware alarm in NetApp SolidFire Active IQ is Alert Name: Host connection and power state and Description: Default alarm to monitor host connection and power state.
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Network_interface_Bond10G_has_a_duplicate_IP_addressApplies to NetApp Element Software NetApp SF-Series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error Code: networkConfig Details: Network interface Bond10G has a duplicate IP address <...Applies to NetApp Element Software NetApp SF-Series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error Code: networkConfig Details: Network interface Bond10G has a duplicate IP address <IP> detected on the network. MAC Addresses with the same IP: {<MAC_Address>}
- https://kb.netapp.com/Legacy/ONTAP/7Mode/AutoSupport_message__ARS_Partial_Path_TransitionData ONTAP 7 and earlier Sysconfig -a with single-path or multi-path under System Storage Configuration Potential Impact: Low Storage with a single path left undiagnosed can cause unexpected outages i...Data ONTAP 7 and earlier Sysconfig -a with single-path or multi-path under System Storage Configuration Potential Impact: Low Storage with a single path left undiagnosed can cause unexpected outages if the remaining path fails. Additionally, there is a potential performance impact when some drives are single-pathed while other members of the raid group are multi-pathed. A combination of drives reporting Primary Port and Secondary Port Some drives reporting Primary Port only in storage show
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Failed_to_balance_interrupts_Performance_may_be_degradedApplies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Failed to balance interrupts. Performance may be degraded Error(s): xUnknownException: bo...Applies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Failed to balance interrupts. Performance may be degraded Error(s): xUnknownException: boost::filesystem::status: Input/output error: "/sf/etc/hardware/irqbalance.json"
- https://kb.netapp.com/Legacy/ONTAP/7Mode/AutoSupport_message__RLM_HEARTBEAT_STOPPEDRLM heartbeat stopped Cluster Notifications continue to be sent from an RLM card which is not connected, generating alerts to the user (RLM HBT STOPPED) CRITICAL and generation of related autosupport ...RLM heartbeat stopped Cluster Notifications continue to be sent from an RLM card which is not connected, generating alerts to the user (RLM HBT STOPPED) CRITICAL and generation of related autosupport emails. The RLM generating the error messages is not connected to the network. Issuing the command rlm reboot does not stop the messages from being generated because it does not reset the configuration of the RLM.
- https://kb.netapp.com/Legacy/ONTAP/Clustered_Data_ONTAP_8/How_to_configure_DNS_per_SVM_for_versions_later_than_clustered_Data_ONTAP_8.2.1Applies to Clustered Data ONTAP 8.2 Description This document explains how to configure DNS per SVM for versions later than clustered Data ONTAP 8.2.1.