Additionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA m...Additionally, one site might be designated as holding 'epsilon' - an extra partial vote that allows quorum to form with only half the sites. 'Epsilon' is not the same as 'master'. In the two-node HA mode, _sitelist contains the HA_CONFIG attribute; this implies that completely different rules are in effect for quorum handling. The typical technique is to cat the /var/rdb/_sitelist, then use the rdb_dump tool to investigate by directing it at the IP addresses of interest (or at localhost).
Applies to ONTAP 9 Cluster network switches Inter-Switch Links (ISL) Issue The following AutoSupport alert is sent when one or more ISLs are down between the two cluster network switches: Message ONTA...Applies to ONTAP 9 Cluster network switches Inter-Switch Links (ISL) Issue The following AutoSupport alert is sent when one or more ISLs are down between the two cluster network switches: Message ONTAP version ClusterIfIslDownWarn_Alert ONTAP 9.9.1 and later SwitchIfIslDownWarn_Alert ONTAP 9.8 and earlier If any of these ports go down, or if they were never configured when the switch was brought online, that alert will be reported at regular intervals, until the configuration is corrected.
Applies to MetroCluster ONTAP 9 ONTAP 8 SyncMirror degraded Description Mirror degraded indicates that an aggregate that was configured as a mirrored aggregate is not mirrored any more. This article d...Applies to MetroCluster ONTAP 9 ONTAP 8 SyncMirror degraded Description Mirror degraded indicates that an aggregate that was configured as a mirrored aggregate is not mirrored any more. This article describes the procedure to be followed to fix a mirror degraded system.
Applies to OnCommand Workflow Automation 5.1Px (WFA) Windows platform Issue An error is returning when attempting to install or upgrade Workflow Automation Could not verify schema validation Success o...Applies to OnCommand Workflow Automation 5.1Px (WFA) Windows platform Issue An error is returning when attempting to install or upgrade Workflow Automation Could not verify schema validation Success or Failure even after 900 seconds. Please verify your install after installation is over.
Applies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Failed to balance interrupts. Performance may be degraded Error(s): xUnknownException: bo...Applies to NetApp Element software NetApp SF-series NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Failed to balance interrupts. Performance may be degraded Error(s): xUnknownException: boost::filesystem::status: Input/output error: "/sf/etc/hardware/irqbalance.json"
This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This s...This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This should be done only when needed and under the direction of NetApp Support.
Applies to NetApp SANtricity® OS Issue An error such as the following is seen in the statecapture logs: ->hwLogShow ----Log Entry #0 OCT-30-2011 12:47:18 AM ---- Proc Memory Single-Bit ECC error at 0x...Applies to NetApp SANtricity® OS Issue An error such as the following is seen in the statecapture logs: ->hwLogShow ----Log Entry #0 OCT-30-2011 12:47:18 AM ---- Proc Memory Single-Bit ECC error at 0x00c40000, syndrome 0x23b0 RPA Memory Single-Bit ECC error at 0x25bf6c140, syndrome 0x2239a620, DIMM 2 Recovery Guru displays the following error: Failure Entry X: RPA_ERR_CTL
Applies to CN1610 Description This article provides minimal steps required in order to set up the Serviceport on the CN1610 as well as SSH in order to remotely access the switch.
KB contains information on when the AutoSupport message "HOST_PORT_FAIL - Disabled by IOM" is sent whenever IOM is detecting an issue with drive and disables port to drive.