Applies to OnCommand Workflow Automation 5.1Px (WFA) Windows platform Issue An error is returning when attempting to install or upgrade Workflow Automation Could not verify schema validation Success o...Applies to OnCommand Workflow Automation 5.1Px (WFA) Windows platform Issue An error is returning when attempting to install or upgrade Workflow Automation Could not verify schema validation Success or Failure even after 900 seconds. Please verify your install after installation is over.
Applies to CN1610 Description This article provides minimal steps required in order to set up the Serviceport on the CN1610 as well as SSH in order to remotely access the switch.
KB article covers the causes and solution steps when EMS message for duplicate IP address (netinet.ethr.duplct.ipAdrr:error) is seen and there is intermittent network connectivity in new vserver.
Applies to ONTAP 9 Cluster network switches Inter-Switch Links (ISL) Issue The following AutoSupport alert is sent when one or more ISLs are down between the two cluster network switches: Message ONTA...Applies to ONTAP 9 Cluster network switches Inter-Switch Links (ISL) Issue The following AutoSupport alert is sent when one or more ISLs are down between the two cluster network switches: Message ONTAP version ClusterIfIslDownWarn_Alert ONTAP 9.9.1 and later SwitchIfIslDownWarn_Alert ONTAP 9.8 and earlier If any of these ports go down, or if they were never configured when the switch was brought online, that alert will be reported at regular intervals, until the configuration is corrected.
Applies to ONTAP Select deployment failed with the following error message : Reason: Can't find label CLENUP at /opt/netapp/lib/DVADMIN/VM.pm How to verify In order to confirm the issue please check t...Applies to ONTAP Select deployment failed with the following error message : Reason: Can't find label CLENUP at /opt/netapp/lib/DVADMIN/VM.pm How to verify In order to confirm the issue please check the VMware logs under the esxiadmin.log.tgz for the following message: [INFO] [Util::error_handler] Permission to perform the operation - Virtual Appliance Create is denied. Reason: NoPermissionFault : Permission to perform this operation was denied. Privilege missing at Datacenter level.
This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This s...This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This should be done only when needed and under the direction of NetApp Support.