Issue

  • The following error is reported while trying to get the environment sensors output from the node:

::> system environment sensors show -node Node-01
Node Sensor                 State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node-01
     PSU2 FRU              normal
                                         GOOD
     PSU1 FRU              normal
              GOOD
     NVDIMM0 Health        normal
                                         GOOD
     NVDIMM1 Health normal
                                         GOOD
     SP Status             normal
IPMI_HB_OK
Warning: Unable to list entries on node Node-01. Timeout: Operation "bmc_client_bmc_get_sensor_info_iterator::modify_imp()" took longer than 25 seconds to complete [from mgwd on node "Node-01" (VSID: -1) to servprocd at 127.0.0.1]
Error: show failed: Timeout: Operation "bmc_client_bmc_get_sensor_info_iterator::modify_imp()" took longer than 25 seconds to complete [from mgwd on node "Node-01" (VSID: -1) to servprocd at 127.0.0.1]
5 entries were displayed.

  • The output of system node power show also fails with the timeout error:

::> system node power show
Node             Status
---------------- -----------
Error: Timeout: Operation "bmc_client_system_power_status_iterator::modify_imp()" took longer than 25 seconds to complete [from mgwd on node "Node-01" (VSID: -1) to servprocd at 127.0.0.1]
Node-01          -
Node-02          -
2 entries were displayed.

  • The following events are seen from the affected node in the SP-MGMT-MLOG-TXT.GZ section:

    [kern_servprocd:info:55561] 0x809824c00: 8503e800016b9888: NOTICE: Servprocd::CLI: get_spcs_port : spcs port value in sp_api_service mdb is 50000
    [kern_servprocd:info:55561] 0x809824c00: 8503e800016b9888: ERR: Servprocd::CLI: sp_get_sensor_info_worker : TTX ERROR: 2 (THRIFT_POLL (timed out))
    [kern_servprocd:info:55561] 0x809824c00: 8503e800016b9888: ERR: Servprocd::CLI: sp_get_sensor_info_worker : EXCEPTION Occured in closing the spcc transport
    [kern_servprocd:info:55561] Thrift: Fri Jul  4 00:14:51 2025 SSL_shutdown: shutdown while in init (SSL_error_code = 1)
    [kern_servprocd:info:55561] 0x809824c00: 8503e800016b9888: ERR: Servprocd::bmc_client: bmc_get_sensor_info_imp: target_node=Node-01, err=The operation timed out.

  • The SP API service internal certificates are renewed as per this KB: Active IQ Wellness Risk: ONTAP reports error when communicating with SP/BMC
  • There are no changes after rebooting the BMC and restarting the service processor daemon.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.