Skip to main content
NetApp Knowledge Base

Environment shutdown due to a FAN failure on AFF A700, FAS9000

Views:
1,261
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • AFF A700 / FAS9000
  • SP firmware version 4.7 or later

Issue

  • Controller powers down, due to "Multiple fans has failed" event, causing a partner takeover.
  • AutoSupport generated: HA Group Notification (MULTIPLE FAN FAILED: System will shut down in 2 minutes) ERROR
  • EMS / event log will show one or more of the following fan errors:

::> event log show -event *fan*

[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F1 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F2 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F3 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F4 at failed
[cluster-01: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[cluster-01: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: FanB1 F1, FanB1 F2, FanB1 F3, FanB1 F4. 
[cluster-01: env_mgr: callhome.c.fan.fru.shut:error]: Call home for MULTIPLE FAN FAILED: System will shut down in 2 minutes
[cluster-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

  • SP syslog (included in sp status -d output) contains:

[477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
[477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures
[477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
[477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures

  • Outputs of system node environment sensors show indicate fault/MULTIFAULT on FRU FanB1 (or other affected fan).

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.