Issue

A critical fault was reported on the DS460C disk storage shelf 21 attached to channel 0b
 
EMS
Mon Aug 11 03:35:54 [node-1: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
Mon Aug 11 03:36:00 [node-1: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 37 C (98 F). This module is on the front of the shelf 3rd drawer from the top, module A sensor 2.
Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 25: not installed or failed. Current temperature: 36 C (96 F). This module is on the front of the shelf 3rd drawer from the top, module B sensor 2.
 
STORAGE-FAULT
Enclosure Status: normal
Channel: 0b
Shelf: 21
Shelf Type: DS460-12
Product Serial Number: xxxxxxxxxxxxxxx
Module Type: IOM12B
 
Disk Elements:
Element Status                  Status Bytes  Status Descriptions
0 [Bay  0]: NOT AVAILABLE     07,00,00,00
1 [Bay  1]: NOT AVAILABLE     07,01,00,00
2 [Bay  2]: NOT AVAILABLE     07,02,00,00
3 [Bay  3]: NOT AVAILABLE     07,03,00,00
4 [Bay  4]: NOT AVAILABLE     07,04,00,00
5 [Bay  5]: NOT AVAILABLE     07,05,00,00
6 [Bay  6]: NOT AVAILABLE     07,06,00,00
7 [Bay  7]: NOT AVAILABLE     07,07,00,00
8 [Bay  8]: NOT AVAILABLE     07,08,00,00
9 [Bay  9]: NOT AVAILABLE     07,09,00,00
10 [Bay 10]: NOT AVAILABLE     07,0A,00,00
11 [Bay 11]: NOT AVAILABLE     07,0B,00,00
12 [Bay  0]: OK                01,00,00,00
13 [Bay  1]: OK                01,01,00,00
14 [Bay  2]: OK                01,02,00,00
15 [Bay  3]: OK                01,03,00,00
16 [Bay  4]: OK                01,04,00,00
17 [Bay  5]: OK                01,05,00,00
18 [Bay  6]: OK                01,06,00,00
19 [Bay  7]: OK                01,07,00,00
20 [Bay  8]: OK                01,08,00,00
21 [Bay  9]: OK                01,09,00,00
22 [Bay 10]: OK                01,0A,00,00
23 [Bay 11]: OK                01,0B,00,00
24 [Bay  0]: OK                01,00,00,00
25 [Bay  1]: OK                01,01,00,00
26 [Bay  2]: OK                01,02,00,00
27 [Bay  3]: OK                01,03,00,00
28 [Bay  4]: OK                01,04,00,00
29 [Bay  5]: OK                01,05,00,00
30 [Bay  6]: OK                01,06,00,00
31 [Bay  7]: OK                01,07,00,00
32 [Bay  8]: OK                01,08,00,00
33 [Bay  9]: OK                01,09,00,00
34 [Bay 10]: OK                01,0A,00,00
35 [Bay 11]: OK                01,0B,00,00
36 [Bay  0]: OK                01,00,00,00
37 [Bay  1]: OK                01,01,00,00
38 [Bay  2]: OK                01,02,00,00
39 [Bay  3]: OK                01,03,00,00
40 [Bay  4]: OK                01,04,00,00
41 [Bay  5]: OK                01,05,00,00
42 [Bay  6]: OK                01,06,00,00
43 [Bay  7]: OK                01,07,00,00
44 [Bay  8]: OK                01,08,00,00
45 [Bay  9]: OK                01,09,00,00
46 [Bay 10]: OK                01,0A,00,00
47 [Bay 11]: OK                01,0B,00,00
48 [Bay  0]: OK                01,00,00,00
49 [Bay  1]: OK                01,01,00,00
50 [Bay  2]: OK                01,02,00,00
51 [Bay  3]: OK                01,03,00,00
52 [Bay  4]: OK                01,04,00,00
53 [Bay  5]: OK                01,05,00,00
54 [Bay  6]: OK                01,06,00,00
55 [Bay  7]: OK                01,07,00,00
56 [Bay  8]: OK                01,08,00,00
57 [Bay  9]: OK                01,09,00,00
58 [Bay 10]: OK                01,0A,00,00
59 [Bay 11]: OK                01,0B,00,00
 
Drawers Control Module:
Element Status                      Status Bytes  Status Descriptions
1 [IOM12B A]    : CRITICAL          02,40,00,00   FAIL
2 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
3 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
4 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
5 [IOM12B A]    : OK                01,00,01,01   REPORT, TYPE BIT0
6 [IOM12B B]    : CRITICAL          02,40,00,00   FAIL
7 [IOM12B B]    : OK                01,00,01,01   REPORT, TYPE BIT0
8 [IOM12B B]    : OK                01,00,01,01   REPORT, TYPE BIT0
9 [IOM12B B]    : OK                01,00,01,01   REPORT, TYPE BIT0
10 [IOM12B B]    : OK                01,00,01,01   REPORT, TYPE BIT0
 
ENVIRONMENT
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29; with error: none
Shelf temperatures by element:
[1] 20 C (68 F) (ambient)  Normal temperature range
[2] 29 C (84 F)  Normal temperature range
[3] 30 C (86 F)  Normal temperature range
[4] 30 C (86 F)  Normal temperature range
[5] 29 C (84 F)  Normal temperature range
[6] 31 C (87 F)  Normal temperature range
[7] 31 C (87 F)  Normal temperature range
[8] 32 C (89 F)  Normal temperature range
[9] 34 C (93 F)  Normal temperature range
[10] Unavailable
[11] 32 C (89 F)  Normal temperature range
[12] 31 C (87 F)  Normal temperature range
[13] 33 C (91 F)  Normal temperature range
[14] 32 C (89 F)  Normal temperature range
[15] Unavailable
[16] 33 C (91 F)  Normal temperature range
[17] 32 C (89 F)  Normal temperature range
[18] 32 C (89 F)  Normal temperature range
[19] 33 C (91 F)  Normal temperature range
[20] Unavailable
[21] 30 C (86 F)  Normal temperature range
[22] 31 C (87 F)  Normal temperature range
[23] 32 C (89 F)  Normal temperature range
[24] 31 C (87 F)  Normal temperature range
[25] Unavailable
[26] 32 C (89 F)  Normal temperature range
[27] 31 C (87 F)  Normal temperature range
[28] 30 C (86 F)  Normal temperature range
[29] 32 C (89 F)  Normal temperature range
 
DCM installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10; with error: 1, 6
DCM information by element:
[1] Serial number:   Part number:
Type:   Vendor:   Firmware version:
[2] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[3] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[4] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[5] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[6] Serial number:   Part number:
Type:   Vendor:   Firmware version:
[7] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[8] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[9] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[10] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.