DS460 Drawer Critical/Critical state and offline aggregates on FAS8300
Applies to
DS460C
Issue
- A FAS8300 system reported a hardware fault where Drawer 1 on shelf 1.10 entered a critical/critical state
- All 12 disks in the drawer showed as unknown container types
- Aggregates aggr0_n1 and aggr1_n1 on node node-01 were offline
Example:cluster::*> storage shelf drawer show
Drawer Shelf Drawer Status A/B Closed? Count Firmware A/B---------------------------------------------------------1.10 1 critical/critical closed 12/...
cluster::*> disk show -container-type unknownUsable Disk Container ContainerDisk Size Shelf Bay Type Type Name Owner---------------------------------------------------------1.10.12 14.26TB 10 12 FSAS unknown - node-01
cluster::*> aggr show
Info: Node node-01 that hosts aggregate aggr0_n1 is offline Node node-01 that hosts aggregate aggr1_n1 is offline