DS4246 disk shelf status non-critical condition
Applies to
DS4246
Issue
Both the HA nodes are indicating non-critical condition
for DS4246 disk shelf.
- EMS log indicates
Power supply 3: normal status
for non-existing PSU. - ENVIRONMENT STATUS indicates
_NO_PSN_PRESENT_
for non-existing PSU. - STORAGE SHOW FAULT indicates
OK
status for non-existing PSU. - ENVIRONMENT STATUS shows number for empty shelf bay
16
. - STORAGE SHOW FAULT indicates
NONCRITICAL
status for empty shelf bay16
.
<EMS>
Mon Jun 21 07:11:51 KST [EMR:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0a power supply information for Power supply 3: normal status.
Mon Jun 21 07:11:51 KST [PACS:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0b power supply information for Power supply 3: normal status.
<ENVIRONMENT STATUS>
Channel: 0a
Shelf: 3
SES device path: local access: 0a.03.99
Module type: IOM6; monitoring is active
Shelf status: non-critical condition
SES Configuration, shelf 3:
logical identifier=0x500a0980083d0635
vendor identification=NETAPP
product identification=DS4246
product revision level=0191
Vendor-specific information:
Product Serial Number: xxxxxxxxxxxxxxx
…
Power Supply installed element list: 1, 3, 4; with error: none
Power Supply information by element:
[1] Serial number: xxxxxxxxxxxxxxx Part number: 114-00087+G0
Type: 9E
Firmware version: 0208 Swaps: 0
[2] Serial number: <N/A> Part number: <N/A>
Type: <N/A>
Firmware version: <N/A> Swaps: 0
[3] Serial number: NO_PSN_PRESENT_ Part number: PPP-PPPPP+XX
Type: 00
Firmware version: 0000 Swaps: 0
[4] Serial number: xxxxxxxxxxxxxxx Part number: 114-00087+G0
Type: 9E
Firmware version: 0208 Swaps: 0
...
Shelf mapping (shelf-assigned addresses) for channel 0a:
Shelf 0: 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Shelf 1: 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Shelf 2: 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Shelf 3: XXX XXX XXX XXX XXX XXX XXX 16 XXX XXX XXX 12 11 10 9 8 7 6 5 4 3 2 1 0
Shelf 4: XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX 12 11 10 9 8 7 6 5 4 3 2 1 0
<STORAGE SHOW FAULT>
Disk Elements:
Element Status Status Bytes Status Descriptions
…
11 [Bay 11]: OK 01,0B,00,00
12 [Bay 12]: OK 01,0C,00,00
13 [Bay 13]: NOT INSTALLED 05,0D,00,00
14 [Bay 14]: NOT INSTALLED 05,0E,00,00
15 [Bay 15]: NOT INSTALLED 05,0F,00,00
16 [Bay 16]: NONCRITICAL 03,10,00,00
17 [Bay 17]: NOT INSTALLED 05,11,00,00
18 [Bay 18]: NOT INSTALLED 05,12,00,00
19 [Bay 19]: NOT INSTALLED 05,13,00,00
20 [Bay 20]: NOT INSTALLED 05,14,00,00
21 [Bay 21]: NOT INSTALLED 05,15,00,00
22 [Bay 22]: NOT INSTALLED 05,16,00,00
23 [Bay 23]: NOT INSTALLED 05,17,00,00
Power Supplies:
Element Status Status Bytes Status Descriptions
1: OK 01,00,00,A0 RQSTED ON
2: NOT INSTALLED 05,00,00,20
3: OK 01,00,00,A0 RQSTED ON
4: OK 01,00,00,A0 RQSTED ON