DS224C

Issue

  • A shelf reports over-temperature
  • EMS Logs report:

[ses.status.temperatureWarning:alert]: DS224-12 (S/N ****) shelf 11 on channel 9c temperature warning for Temperature sensor 1: non-critical status; overtemperature warning. Current temperature: 52 C (125 F). This module is on the front of the shelf on the left, on the OPS panel.
[statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 9b. Check fans, power supplies, disks, and temperature sensors.
[statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 9b. Check fans, power supplies, disks, and temperature sensors.

  • ENVIRONMENT log:

Channel: 9b
Shelf: 11
SES device path: local access: 9c.11.99
Module type: IOM12B; monitoring is active
Shelf status: non-critical  condition
SES Configuration, shelf 11:
 vendor identification=NETAPP
 product identification=DS224-12
 product revision level=0130
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11; with error: 1
        Shelf temperatures by element:
          [1] 52 C (125 F) (ambient) Overtemperature warning!
          [2] 27 C (80 F)  Normal temperature range
          [3] 27 C (80 F)  Normal temperature range
          [4] 28 C (82 F)  Normal temperature range
          [5] 28 C (82 F)  Normal temperature range
          [6] 28 C (82 F)  Normal temperature range
          [7] 46 C (114 F)  Normal temperature range
          [8] 29 C (84 F)  Normal temperature range
          [9] 49 C (120 F)  Normal temperature range
          [10] 32 C (89 F)  Normal temperature range
          [11] 34 C (93 F)  Normal temperature range
        Temperature thresholds by element:
          [1] High critical: 52 C (125 F); high warning: 47 C (116 F)
              Low critical:  0 C (32 F); low warning:  5 C (41 F)
          [2] High critical: 60 C (140 F); high warning: 55 C (131 F)
              Low critical:  0 C (32 F); low warning:  5 C (41 F)
          [3] High critical: 60 C (140 F); high warning: 55 C (131 F)


Enclosure Status: non-critical
Channel: 9b
Shelf: 11
Shelf Type: DS224-12
Product Serial Number: ****
Module Type: IOM12B
Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: NONCRITICAL       03,00,48,04   OT WARNING
  2: OK                01,00,2F,00
  3: OK                01,00,2F,00
  4: OK                01,00,30,00
  5: OK                01,00,30,00
  6: OK                01,00,30,00
  7: OK                01,00,42,00
  8: OK                01,00,31,00
  9: OK                01,00,45,00

 
  • Performing an SP reboot, the error does not disappear.
  • Checking the temperature near the OPS panel of Shelf, there is no abnormal temperature rise.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.