Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/sysconfig_a_reports_Shelf_Serial_Number_instead_of_Shelf_ID_after_IOM_reseat_replacementsysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial...sysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial Number ' SHM09797XXXXX', Product 'DS424IOM3 ', Rev '0172', Slot B You might receive a duplicate shelf ID error in the messages log: [sas.shelf.conflict:error]: At least two SAS disk shelves have the same disk shelf ID.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_map_DS424x_elements_by_error_messages_and_SES_codes_to_a_physical_location_on_the_shelfApplies to Data ONTAP 7 and earlier DS424x Description Unrecoverable condition is reported: [ses_admin:error]:DiskShelf shelf [shelf] on channel [channel]. Map the 8 voltage and 12 temperature sensors...Applies to Data ONTAP 7 and earlier DS424x Description Unrecoverable condition is reported: [ses_admin:error]:DiskShelf shelf [shelf] on channel [channel]. Map the 8 voltage and 12 temperature sensors to the FRU or shelf location on the DS424x shelf.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/In-Band_ACP_Setup_and_SupportThis article outlines how to migrate from OOB to In-Band ACP support - the default in ONTAP 9.0 and later. There must be dual path to each IOM to support In-Band ACP Starting with AFF A700, AFF A300, ...This article outlines how to migrate from OOB to In-Band ACP support - the default in ONTAP 9.0 and later. There must be dual path to each IOM to support In-Band ACP Starting with AFF A700, AFF A300, AFF A200 and FAS9000, FAS8200, and FAS2600 series storage systems, OOB ACP is not supported. Replace IOM3 modules with IOM6 modules, and/or use IOM12 modules to provide In-Band ACP support for all storage (recommended by NetApp). Migrate to In-Band ACP, but without any ACP support for IOM3 modules.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Ambient_temperature_alerts_due_to_a_faulty_OPS_panelApplies to DS2246 DS212C Issue Temperature error in a shelf. Example: Temperature sensor 1: non-critical status warnings Shelf temperatures by element: [1] 41 C (105 F) (ambient) Overtemperature warni...Applies to DS2246 DS212C Issue Temperature error in a shelf. Example: Temperature sensor 1: non-critical status warnings Shelf temperatures by element: [1] 41 C (105 F) (ambient) Overtemperature warning! No environmental issues in the Data Center No issues with the same sensor in any other shelf No temperature issues found in the sensor area (OPS Panel) when using an external temperature reader tool
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/DS4246_disk_shelf_status_non-critical_conditionMon Jun 21 07:11:51 KST [EMR:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0a power supply information for Power supply 3: normal status. Mon Jun 21 07:11:51 KST [PACS:ses.s...Mon Jun 21 07:11:51 KST [EMR:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0a power supply information for Power supply 3: normal status. Mon Jun 21 07:11:51 KST [PACS:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0b power supply information for Power supply 3: normal status. Shelf 3: XXX XXX XXX XXX XXX XXX XXX 16 XXX XXX XXX 12 11 10 9 8 7 6 5 4 3 2 1 0 Shelf 4: XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX 12 11 10 9 8 7 6 5 4 3 2 1 0
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_remove_a_shelf_from_ONTAPApplies to ONTAP 9 Disk shelves DS212C DS224X DS424X DS4486 DS460C Description Before removing a shelf the data needs to be evacuated and ownership and partitioning removed.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_have_no_signal_from_the_same_shelf_bay[?] Mon Jan 16 01:50:01 KST [node02: disk_server_0:disk.IO.status:debug]: params: {'deviceName': '0d.10.3', 'returnCode': '2','pathRetryCount': '0', 'adapterStatus': '0xd', 'cdb':'0x88:000000012228408...[?] Mon Jan 16 01:50:01 KST [node02: disk_server_0:disk.IO.status:debug]: params: {'deviceName': '0d.10.3', 'returnCode': '2','pathRetryCount': '0', 'adapterStatus': '0xd', 'cdb':'0x88:0000000122284080:00000240', 'basicTimeout': '10', 'iASCQ': '0x0','iSenseKey': '0x0', 'sSenseCode': '', 'ETime': '10568', 'iASC': '0x0','victimRetryCount': '10', 'sSenseKey': 'SCSI:no sense', 'targetStatus': '0x0','disk_information': 'Disk 0d.10.3 Shelf 10 Bay 3 [NETAPP X308_HMRKP03TSSM NA00] S/N [xxxxxxxx] UID[50…
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_reboot_because_of_Multi_Disk_Panic_with_one_or_more_shelves_missingraid type raid_dp in SK process config_thread on release 8.2.3P4 on Mon Feb 10 07:52:07 CET 2020version: 8.2.3P4: Fri May 29 14:06:54 PDT 2015compile flags: x86_64Writing panic info to HA mailbox disk...raid type raid_dp in SK process config_thread on release 8.2.3P4 on Mon Feb 10 07:52:07 CET 2020version: 8.2.3P4: Fri May 29 14:06:54 PDT 2015compile flags: x86_64Writing panic info to HA mailbox disks.HA: current time (in sk_msecs) 128169944521 (in sk_cycles) 299073053244098161CF monitor: takeover will occur on reboot If the shelf containing root aggregate disks, which includes mailbox disks, goes offline, partner will be unable to takeover and will generate Active IQ alert:
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/False_PSU2_and_3_alerts_in_System_Manager_for_DS4246_shelvesApplies to DS4246 ONTAP 9 Issue System manager shows PSU2 and PSU3 errors, but no PSUs are installed in these slots. PSU slots 2 & 3 have PSU blanks installed No shelf faults present No fault LEDs lit...Applies to DS4246 ONTAP 9 Issue System manager shows PSU2 and PSU3 errors, but no PSUs are installed in these slots. PSU slots 2 & 3 have PSU blanks installed No shelf faults present No fault LEDs lit on the shelf Confirm the shelf does not require 4 PSUs
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/IOM_upgrade_requires_a_cold_swapThis article describes the steps required for a cold-swap upgrade. When replacing the IOM module in a shelf with a different model it requires the following components to be powered off during the cha...This article describes the steps required for a cold-swap upgrade. When replacing the IOM module in a shelf with a different model it requires the following components to be powered off during the change: ALL nodes that connect to the impacted shelves. ALL ATTO bridges (if applicable) that connect to the impacted shelves. The shelves of which the IOM model will be changed. IOM3 to IOM6 IOM3 to IOM12* IOM6 to IOM12* *Be aware of SAS port differences between IOM3/IOM6 (QSFP) and IOM12 (MiniSAS-HD)