Issue

  • Persistent loss of communication with shelf module IOMB on DS460-12 shelf (Shelf 6), resulting in repeated “unknown link rate” alerts and “SAS disk shelf detected without a multipath configuration” errors.
  • Attempts to resolve with IOMB, SAS cable, and chassis replacements did not fix the issue.
  • System logs show repeated handshake errors and PCD error count increments on multiple PHYs. Shelf remained in a non-normal state with critical alerts for the IOMB module.
  • SYSCONFIG -A of cluster ha can not display shelf 6 IOM B info:
    Shelf 6: DS460-12  Firmware rev. IOM12B A: 0141   B: ----

last IOM fw version is  IOM12B 0202

  • STORAGE-FAULT :
    Enclosure Status: normal
    Channel: 10a
    Shelf: 6
    Shelf Type: DS460-12
    Product Serial Number: xxxx
    Module Type: IOM12B
    Enclosure Electronics:
    Element Status                      Status Bytes  Status Descriptions
      1 [IOM12B A]    : OK                01,00,01,00   REPORT
      2: NOT INSTALLED     05,00,00,00

Enclosure:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,02,00   FAIL


Vendor Unique Element 83-IOM12B: (SAS)
Element Status         Status Bytes  Status Descriptions
  1 [IOM12B A]    : OK                01,08,00,20   MASTER, RESERVED
  2: NOT INSTALLED     05,00,00,00

Vendor Unique Element 85-IOM12B: (ACP)
Element Status                      Status Bytes  Status Descriptions
  1 [IOM12B A]    : CRITICAL          02,18,00,40   NO ACPP, INBACP, FAIL
  2             : NOT INSTALLED     05,18,00,00

  • EMS log:

[?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "1", PHY "0" is reporting an unknown link rate.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "2", PHY "0" is reporting an unknown link rate.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "3", PHY "0" is reporting an unknown link rate.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "4", PHY "0" is reporting an unknown link rate.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "5", PHY "0" is reporting an unknown link rate.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
 [?]  Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.