DS460-12 Shelf: Persistent IOMB Loss and Multipath Errors
Applies to
- DS460-12 Disk Shelf
- FAS9000
- ONTAP 9.11.1P15
- SAS-connected shelves with IOM12B modules
Issue
- Persistent loss of communication with shelf module IOMB on DS460-12 shelf (Shelf 6), resulting in repeated “unknown link rate” alerts and “SAS disk shelf detected without a multipath configuration” errors.
- Attempts to resolve with IOMB, SAS cable, and chassis replacements did not fix the issue.
- System logs show repeated handshake errors and PCD error count increments on multiple PHYs. Shelf remained in a non-normal state with critical alerts for the IOMB module.
- SYSCONFIG -A of cluster ha can not display shelf 6 IOM B info:
Shelf 6: DS460-12 Firmware rev. IOM12B A: 0141 B: ----
last IOM fw version is IOM12B 0202
- STORAGE-FAULT :
Enclosure Status: normalChannel: 10aShelf: 6Shelf Type: DS460-12Product Serial Number: xxxxModule Type: IOM12BEnclosure Electronics:Element Status Status Bytes Status Descriptions1 [IOM12B A] : OK 01,00,01,00 REPORT2: NOT INSTALLED 05,00,00,00
Enclosure:Element Status Status Bytes Status Descriptions 1: OK 01,00,02,00 FAIL
Vendor Unique Element 83-IOM12B: (SAS)Element Status Status Bytes Status Descriptions 1 [IOM12B A] : OK 01,08,00,20 MASTER, RESERVED 2: NOT INSTALLED 05,00,00,00
Vendor Unique Element 85-IOM12B: (ACP)Element Status Status Bytes Status Descriptions 1 [IOM12B A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL 2 : NOT INSTALLED 05,18,00,00
- EMS log:
[?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "1", PHY "0" is reporting an unknown link rate. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "2", PHY "0" is reporting an unknown link rate. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "3", PHY "0" is reporting an unknown link rate. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "4", PHY "0" is reporting an unknown link rate. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "6", module "B", drawer "5", PHY "0" is reporting an unknown link rate. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration. [?] Thu Sep 04 13:49:31 +0800 [node07: dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.