Amber LED after disk replacement due to disk autoassign misconfiguration
- Views:
- 1,421
- Visibility:
- Public
- Votes:
- 0
- Category:
- disk-drives
- Specialty:
- HW
- Last Updated:
- 11/5/2020, 12:59:08 PM
Applies to
- All FAS/AFF platforms.
- ONTAP 9
Issue
- After disk replacement the Amber LED is ON
- Fault status reported by drive:
cluster::> system node run -node node1 -command storage show fault -v
18 [Bay 18]: OK 01,12,00,20 FAULT REQSTD