Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 4 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/CHASSIS_POWER_DEGRADED__Power_Supply_Status_Critical__PSU1_PSU2_ERROR_AutoSupport_message_occurs
      AutoSupport is triggered that the chassis power supply are degraded. HA Group Notification from node-02 (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR [node-02: monitor: mon...AutoSupport is triggered that the chassis power supply are degraded. HA Group Notification from node-02 (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR [node-02: monitor: monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU1, PSU2. [node-02: power_low_monitor: monitor.chassisPowerSupplies.ok:info]: Chassis power supplies OK [node-02: monitor: monitor.globalStatus.ok:info]: The system's global status is normal
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Fault_LED_is_lit_for_no_apparent_reason_on_a_FAS_or_AFF_HA_storage_system_with_internal-only_SAS_storage
      C, SAS, <UP>) Firmware rev: 01.11.06.00 Base WWN: 5:00a098:00361ff:74 Phy State: [4] Enabled, 6.0 Gb/s [5] Enabled, 6.0 Gb/s [6] Enabled, 6.0 Gb/s [7] Enabled, 6.0 Gb/s QSFP Vendor: Amphenol QSFP Part...C, SAS, <UP>) Firmware rev: 01.11.06.00 Base WWN: 5:00a098:00361ff:74 Phy State: [4] Enabled, 6.0 Gb/s [5] Enabled, 6.0 Gb/s [6] Enabled, 6.0 Gb/s [7] Enabled, 6.0 Gb/s QSFP Vendor: Amphenol QSFP Part Number: 112-00176+A0 QSFP Type: Passive Copper 0.5m ID:01 QSFP Serial Number: APF14131767EDC
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Amber_LED_after_disk_replacement_due_disk_autoassign_misconfiguration
      Applies to All FAS/AFF platforms. ONTAP 9 Issue After disk replacement the Amber LED is ON Fault status reported by drive: cluster::> system node run -node node1 -command storage show fault -v 18 [Bay...Applies to All FAS/AFF platforms. ONTAP 9 Issue After disk replacement the Amber LED is ON Fault status reported by drive: cluster::> system node run -node node1 -command storage show fault -v 18 [Bay 18]: OK 01,12,00,20 FAULT REQSTD
    • https://kb.netapp.com/Legacy/ONTAP/7Mode/BIOS_update_fails_with_SPI_device_not_supported_message
      Updating the BIOS when performing an ONTAP upgrade from 8.2.2P1 to 8.2.5P5, fails with the following error: [2021-02-02 11:07:08.586] New BIOS Version: 8.3.0 [2021-02-02 11:07:08.633] SPI device not s...Updating the BIOS when performing an ONTAP upgrade from 8.2.2P1 to 8.2.5P5, fails with the following error: [2021-02-02 11:07:08.586] New BIOS Version: 8.3.0 [2021-02-02 11:07:08.633] SPI device not supported, Trying default command set [2021-02-02 11:07:08.680] SPI device not supported, Trying default command set [2021-02-02 11:07:08.742] Saving Primary Image to Backup flash device [2021-02-02 11:07:08.867] Programming Failed. -4 bytes written: I/O error 0 bytes written: I/O error