Error: Breakout map of 10g-4x is not supported on a 100G optic transceiver
Applies to
- ONTAP 9
- Cisco Nexus (NX) 3232C Cluster Network Switches
- Reference Configuration File (RCF)
Issue
- After applying Nexus-3232C Cluster-HA-Breakout RCF (Example: Nexus-3232C-RCF-v1.8-Cluster-Breakout.txt), Ethernet interfaces will not show any configuration:
interface Ethernet1/30
interface Ethernet1/31
interface Ethernet1/32
interface Ethernet1/33
interface Ethernet1/34
- Switch log errors:
cs2# copy Nexus-3232C-RCF-v1.8-Cluster-Breakout.txt running-config ec ho-commands
`cs2# config terminal`
`cs2(config)# banner motd #`
`cs2(config)# interface breakout module 1 port 1-3 map 10g-4x`
Error: Breakout map of 10g-4x is not supported on a 100G optic transceiver
...
...
`cs2(config)# interface e1/1/1-4, e1/2/1-4, e1/3/1-4, e1/4/1-4, e1/5/1-4, e1/6/1-4, e1/7-30, e1/33-34`
^
Invalid range at '^' marker.
`cs2(config)# inherit port-profile CLUSTER`
^
% Invalid command at '^' marker.
`cs2(config)# priority-flow-control mode auto`
...
...
- Errors will continue until the RCF lines are complete:
% Invalid command at '^' marker.
`cs2# end`
`cs2# end`
Copy complete, now saving to disk (please wait)...
Copy complete.