    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/Error__Breakout_map_of_10g_4x_is_not_supported_on_a_100G_optic_transceiver
      After applying Nexus-3232C Cluster-HA-Breakout RCF (Example: Nexus-3232C-RCF-v1.8-Cluster-Breakout.txt), Ethernet interfaces will not show any configuration: `cs2(config)# interface breakout module 1 ...After applying Nexus-3232C Cluster-HA-Breakout RCF (Example: Nexus-3232C-RCF-v1.8-Cluster-Breakout.txt), Ethernet interfaces will not show any configuration: `cs2(config)# interface breakout module 1 port 1-3 map 10g-4x` Error: Breakout map of 10g-4x is not supported on a 100G optic transceiver `cs2(config)# interface e1/1/1-4, e1/2/1-4, e1/3/1-4, e1/4/1-4, e1/5/1-4, e1/6/1-4, e1/7-30, e1/33-34` Errors will continue until the RCF lines are complete:
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Upgrading_Cluster_Switch_to_RCF_v1.4_Causes_Cluster_Ports_To_Go_Offline_After_Reboot
      Applies to ONTAP 9 Cisco Nexus (NX) Cluster Network Switches Reference Configuration File (RCF) Issue Cluster switch upgraded from RCF 1.1/1.2 to RCF 1.4 to take advantage of switch HA for AFF A320's ...Applies to ONTAP 9 Cisco Nexus (NX) Cluster Network Switches Reference Configuration File (RCF) Issue Cluster switch upgraded from RCF 1.1/1.2 to RCF 1.4 to take advantage of switch HA for AFF A320's After reboot to commit RCF, cluster ports go offline causing loss of redundancy Cluster ports remain online for the partner switch still running RCF 1.1/1.2
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/Cisco_Nexus_Switch_shows_PSU_Fan_shutdown
      Cisco Nexus Cluster Network Switch Node reports health alert notificaiton for switch PSU fan not opertional HMSPFE:HA Group Notification from Node-01 (Health Monitor process cshm: SwitchPsuFanNotOpera...Cisco Nexus Cluster Network Switch Node reports health alert notificaiton for switch PSU fan not opertional HMSPFE:HA Group Notification from Node-01 (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch-01(xxxxxxxxxxxxx)/PowerSupply-2 Fan-1]) ALERT show environment reports fan and power supply for switch as shutdown Fan1(sys_fan1) NXA-FAN-65CFM-PE -- back-to-front Ok 1 NXA-PAC-1100W-PE2 264 W 294 W 1100 W Ok 2 NXA-PAC-1100W-PE2 0 W 0 W 0 W Shutdown
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/RCF_Improperly_Applied_to_Cluster_Network_Switch_Requiring_RCF_Revert
      An RCF has been improperly applied, and is noticed when reviewing the running configuration with the show running-config command; attempts to re-apply the correct RCF do not resolve the issue Cluster ...An RCF has been improperly applied, and is noticed when reviewing the running configuration with the show running-config command; attempts to re-apply the correct RCF do not resolve the issue Cluster network degraded Autosupport callhomes may be generated on a daily basis due to the following cluster network ping loss errors between all nodes in the cluster
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/How_to_find_Management_Information_Base_MIB_files_for_the_CISCO_Nexus_switches
      Applies to CISCO Nexus Switch Answer Required documents to set up CISCO Nexus Switches Please contact Cisco Technical Assistance Center for further assistance. Additional Information How to create a c...Applies to CISCO Nexus Switch Answer Required documents to set up CISCO Nexus Switches Please contact Cisco Technical Assistance Center for further assistance. Additional Information How to create a case with Cisco Support