Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_redundancy_failed_error_and_wrong_SAS_speed_in_a_disk_bayTue Feb 02 14:34:30 +0100 [node_name: dsa_worker0: ds.sas.drivephy.disableErr:error]: Disk [NETAPP :X336_HAKPE04TA07:NA00] S/N [01234567] on channels 0b shelf ID 0 IOM B bay 4 disabled due to excessiv...Tue Feb 02 14:34:30 +0100 [node_name: dsa_worker0: ds.sas.drivephy.disableErr:error]: Disk [NETAPP :X336_HAKPE04TA07:NA00] S/N [01234567] on channels 0b shelf ID 0 IOM B bay 4 disabled due to excessive invalid dword error.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_only_shows_one_path_on_NS224_Shelf_Disk_Redundancy_Errors01.0.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.0.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.0.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/...01.0.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.0.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.0.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.3.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.3.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX) 01.3.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Call_home_for_DISK_REDUNDANCY_FAILED_alert_after_takeover[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED [?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.adapter.debug:info]: par...[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED [?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Link down too long ... offlining', 'adapterName': '0b'} [?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.link.error:error]: Could not recover link on SAS adapter 0b after 45 seconds.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disk_redundancy_failed_for_disk_with_one_path_only_on_NVMe_shelfDevice Port Negotiated Medium Device Port Negotiated Received Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable Id State Speed Speed Spe...Device Port Negotiated Medium Device Port Negotiated Received Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable Id State Speed Speed Speed Speed Width width width Count Count Count Errors Errors (GT/s) (GT/s) (GT/s) (GT/s) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ (...) [ 20] OK 8.0 8.0 8.0 8.0 4 2 2…
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/PHY_is_reporting_an_unknown_link_rate_for_a_disk_in_DS460C_drawer_after_disk_and_IOM_re_seatDisk bypassed by the IOMs in the AutoSupport STORAGE-FAULT or ::> system node run -node node_name -command storage show fault -v” output. [node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Dri...Disk bypassed by the IOMs in the AutoSupport STORAGE-FAULT or ::> system node run -node node_name -command storage show fault -v” output. [node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "A", drawer "3", PHY "1" is reporting an unknown link rate. [node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "B", drawer "3", PHY "1" is reporting an unknown link rate. ::> storage disk show -disk 1.1.27
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/PHY_is_reporting_an_unknown_link_rate_for_disk_in_DS460C_drawerDisk bypassed by one IOM: System ID: 0123456789 (node_name-01); partner ID: 0123456780(node_name-02) Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf...Disk bypassed by one IOM: System ID: 0123456789 (node_name-01); partner ID: 0123456780(node_name-02) Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf 1, module B, drawer 1, PHY 1 is reporting an unknown link rate. Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED Element Status Status Bytes Status Descriptions Issue remains after disk re-seat and replacement:
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Single_disk_is_missing_on_NS224_shelfNetApp single-disk goes missing on NS224 shelf on both paths.
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/DISK_REDUNDANCY_FAILED_alerts_reporting_due_to_remote_drives_missing_in_Fabric_MetroclusterApplies to nscamshow displays :No entry is found! Nodes are missing remote disks due to loss of one or more paths and reports the below EMS events, [?] Thu Jan 14 13:46:08 CET [Node-A: svc_queue_threa...Applies to nscamshow displays :No entry is found! Nodes are missing remote disks due to loss of one or more paths and reports the below EMS events, [?] Thu Jan 14 13:46:08 CET [Node-A: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED Brocade switches shows no remote devices from nscamshow -t command output and also sometimes the zone reports fabric is busy, nscam show for remote switches: No entry is found! The Fabric is busy, try again later.