Disk only shows one path on NS224 Shelf (Disk Redundancy Errors)
Applies to
- ONTAP 9
- NS224 (NSM100)
Issue
- Disk X.XX.XX showing only one path. Data ONTAP triggers call home for DISK REDUNDANCY FAILED
- Drive is missing on one path on both nodes as illustrated below:
ClusterA-01::> sysconfig -a
e1a MAC Address: d0:00:aa:00:00:00 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486860
01.0.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.0.1: NETAPP X4011S172B3T8NTE NA56 3662.5GB 4160B/sect (S57YXXXXXXXXXX)
01.0.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.0.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
e1b MAC Address: d0:39:ea:49:13:41 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486668
01.3.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
<No Drive 1 listed here as expected>
01.3.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.3.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
ClusterA-02::> sysconfig -a
e1a MAC Address: d0:39:ea:XX:XX:XX(auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21419478411
01.2.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
<No Drive 1 listed here as expected>
01.2.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.2.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
e1b MAC Address: d0:39:ea:XX:XX:XX (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486707
01.1.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.1.1: NETAPP X4011S172B3T8NTE NA56 3662.5GB 4160B/sect (S57YXXXXXXXXXX)
01.1.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.1.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
- At times the disk might be completely missing. Data ONTAP triggers call home for FILESYSTEM DISK MISSING