Call home for DISK REDUNDANCY FAILED alert after takeover
Applies to
- 8.2.5P5 7-MODE
- FAS2552
Issue
- EMS log show
Call home for DISK REDUNDANCY FAILED
:
[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: shelf.config.tospha:info]: System has transitioned to single path HA attached storage
[?] Sun Jul 25 09:59:00 CST [Node_B: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- Port 0b went offline :
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (hard)>)
Firmware rev: 01.12.09.00
Base WWN: x:xxxxx:xxxxxxx:xx
Phy State: [4] Enabled, Rate unknown
[5] Enabled, Rate unknown
[6] Enabled, Rate unknown
[7] Enabled, Rate unknown
- EMS log has error information about port 0b :
[?] Sun Jul 25 09:43:16 CST [Node_B: pmcsas_intrd_0: sas.port.down:warning]: SAS port "0b" went down.
[?] Sun Jul 25 09:43:47 CST [Node_B: sinai_link_mgr: cf.ic.sbb:debug]: HA interconnect: SBB Compatibility Event. No compatible partner node found. The interconnect device has been disabled.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Link down too long ... offlining', 'adapterName': '0b'}
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_timeout_0: sas.link.error:error]: Could not recover link on SAS adapter 0b after 45 seconds. Offlining the adapter.
[?] Sun Jul 25 09:44:02 CST [Node_B: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'pmcsas_asyncd_offline', 'adapterName': '0b'}