Disk redundancy failed for disk with one path only on NVMe shelf
Applies to
- All Flash Fas (AFF)
- NS224 shelf
- A800 internal shelf
Issue
- An expansion card and a NS224 shelf were added to an HA-pair
- Cabling is found to be correct
- All disks are added to the disk inventory
- Call home for
DISK REDUNDANCY FAILEDAuto Support alert is seen right after System Storage ConfigurationshowsMixed-Path HA- EMS shows
Wed Nov 10 11:22:31 +0100 [Node-01: rshd_0: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations. Wed Nov 10 11:22:31 +0100 [Node-02: rshd_0: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
- Both nodes report the disk only on one path.
Example:
ClusterA::> run -node Node-01 sysconfig -a
shows for for each node/path:
NetApp Release 9.9.1P3: Wed Sep 29 09:06:45 EDT 2021
System ID: 0537412960 (Node-01); partner ID: 0537412973 (Node-02)
System Serial Number: xxxxxx (Node-01)
System Rev: A6
System Storage Configuration: Mixed-Path HA
slot 1: 100G Ethernet Controller CX6-Mezze1a MAC Address: xx:xx:xx:xx:xx:2e (auto-100g_cr4-fd-up)QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A2117520794
11.2.0: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301728)
11.2.1: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301733)
11.2.2: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301717)
11.2.20: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301716)
11.2.21: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301736)
11.2.22: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301738)
11.2.23: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301730)
Shelf 11: NS224NSM100 Firmware rev. NSM100 A: 0141 NSM100 B: 0141e1b MAC Address: xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A2117520700
11.1.0: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301728)
11.1.1: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301733)
11.1.2: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301717)
11.1.20: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301716)
11.1.22: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301738) 11.2.21 missing here11.1.23: NETAPP X4010S17331T9NTE NA51 1831.1GB 4160B/sect (S60PNA0R301730)
Shelf 11: NS224NSM100 Firmware rev. NSM100 A: 0141 NSM100 B: 0141- In the
storage shelf showinfo we see that one link is incorrectly initialized and the port is disabled
Example:
cluster1::> storage shelf show
Shelf name: 0x.shelf11
Shelf id: 11
Channel: 0x
Module: A
Shelf UID: 00:a0:xx:xx:xx:xx:xx:xx
Shelf S/N: SHFHUxxxxxxxxx
Term switch: N/A
Shelf state: ONLINE
Module state: OK
Device Port Negotiated Medium Device Port Negotiated Received
Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable
Id State Speed Speed Speed Speed Width width width Count Count Count Errors Errors
(GT/s) (GT/s) (GT/s) (GT/s)
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
(...)
[ 20] OK 8.0 8.0 8.0 8.0 4 2 2 0 0 0 0 8192
[ 21] DIS/DLL 8.0 8.0 2.5 8.0 4 2 0 0 0 0 0 8193
[ 22] OK 8.0 8.0 8.0 8.0 4 2 2 0 0 0 0 0
[ 23] OK 8.0 8.0 8.0 8.0 4 2 2 0 0