Skip to main content
NetApp Knowledge Base

Error symbol and Illegal symbol count incrementing on a NIC port

Views:
1,327
Visibility:
Public
Votes:
2
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS, AFF
  • Network port
  • ONTAP 9.2 or higher.

Issue

  • CRC errors reported in EMS messages. Example:

[node_name: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0g on node node_name is reporting a high number of observed hardware errors, possibly CRC errors.

  • Increasing Error and/or Illegal symbol count observed in ifstat -a output of that NIC port, along with CRC errors. Example:

::> system node run -node <node_name> -command ifstat <port_name>
    -- interface  e0g  (123 days, 4 hours, 5 minutes, 6 seconds) --
    RECEIVE
    Total frames:      117g | Frames/second:    1798  | Total bytes:       175t
    Bytes/second:     2680k | Total errors:     1538k | Errors/minute:       1
     Total discards:      0  | Discards/minute:     0  | Multi/broadcast: 31222k
    Non-primary u/c:     0  | CRC errors:       1522k | Runt frames:         0
     Fragment:         1107  | Long frames:         0  | Jabber:              0
     Length errors:      96  | No buffer:           0  | Xon:                 0
     Xoff:                0  | Pause:               0  | Jumbo:               0
     Noproto:             0  | Error symbol:     1234  | Illegal symbol:    5678
    ...

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.