SolidFire Hardware KBs
SolidFire Hardware KBs
Featured
Unresponsive BMC
Troubleshooting unresponsive BMC on H610S
Troubleshooting unresponsive BMC on H610S
BMC Self Test
BMC Self Test failed
BMC Self Test failed
SensorReadingFailed
SensorReadingFailed': IPMI diagnostics are currently unresponsive
SensorReadingFailed': IPMI diagnostics are currently unresponsive
Input Missing or Out of Range
Power supply PSx input missing or out of range
Power supply PSx input missing or out of range
DriveAvailableWarning
DriveAvailable Warning AutoSupport Message
DriveAvailable Warning AutoSupport Message
Other Resources
- Unable to access H410S IPMI via shared port after power drainThu, 05 Dec 2024
- SF19210-all drives marked as DriveMissing and then moved to available stateTue, 26 Nov 2024
- H610S BMC WebUI can't access after IP changedSat, 23 Nov 2024
- Power supply PS2 input missing or out of rangeFri, 01 Nov 2024
- All storage nodes report SensorReadingFailed, bmcTestFailed and not resolved by power drainTue, 15 Oct 2024
- NETWORK_FIRMWARE_VERSION_ETH3 should be >= 0x80000aee but is nullFri, 30 Aug 2024
- One drive has not been detected after H610S node replacementThu, 29 Aug 2024
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issueMon, 26 Aug 2024
- How to set BMC time of H410 series using IPMI WebUIMon, 19 Aug 2024
- Mellanox Switch no longer accessibleWed, 14 Aug 2024
- ASUP_PP SolidFire Alert from (Drive Available)Wed, 07 Aug 2024
- Where can hardware information about H-series compute node components be found?Thu, 01 Aug 2024
- SolidFire Link down detects continuallyWed, 24 Jul 2024
- Solid Red information LED on H410S nodeWed, 24 Jul 2024
- What is the meaning of the "i" LED on H410S Nodes?Wed, 24 Jul 2024
- How to set BMC time using ipmitool in mNodeTue, 23 Jul 2024
- Converting a 2-Cable VDS Configuration to a 6-Cable VSS ConfigurationWed, 10 Jul 2024
- SolidFire node will not add to the cluster and gives MTU failure errorThu, 16 May 2024
- Nodes stuck in boot loop after power maintenanceFri, 10 May 2024
- How To Upgrade Compute Node FirmwareMon, 29 Apr 2024
- Unable to access H410S IPMI via shared port after power drainThu, 05 Dec 2024
- Multiple Drives moved to 'Available' pool on Element nodeMon, 02 Dec 2024
- Rebranding of H700S nodes to H410SFri, 29 Nov 2024
- Persistent blockClusterFull alerts on Element storage clusterTue, 26 Nov 2024
- SF19210-all drives marked as DriveMissing and then moved to available stateTue, 26 Nov 2024
- AutoSupport Message: Power supply PSx input missing or out of rangeMon, 25 Nov 2024
- H610S BMC WebUI can't access after IP changedSat, 23 Nov 2024
- vCenter Alert "Bootbank cannot be found at path '/bootbank"Wed, 20 Nov 2024
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element softwareTue, 12 Nov 2024
- Missing storage node serial number in NetApp SolidFire Active IQMon, 11 Nov 2024
- Authentication Failure messages in Event Log originating from 127.0.0.1Mon, 11 Nov 2024
- Element UI alert shows "MEMORY_GB should be >= <x> but is <x>"Thu, 07 Nov 2024
- fileSystemIsReadOnly fault on Element clusterWed, 06 Nov 2024
- Power supply PS2 input missing or out of rangeFri, 01 Nov 2024
- How are the blockSpace thresholds calculated for ElementThu, 31 Oct 2024
- ExcessiveCapacitorVoltage alert on NetApp Element storage nodesWed, 30 Oct 2024
- How to run VAAI UNMAP and return capacity to ElementFri, 25 Oct 2024
- SolidFire node offline due to DBClient in an invalid stateWed, 23 Oct 2024
- NETWORK_FIRMWARE_VERSION_ETH3 should be >= 0x80000aee but is nullTue, 22 Oct 2024
- BMC SEL error: Volt_P3V_BAT Voltage Lower CriticalMon, 21 Oct 2024