SolidFire Hardware KBs
SolidFire Hardware KBs
Featured
Unresponsive BMC
Troubleshooting unresponsive BMC on H610S
Troubleshooting unresponsive BMC on H610S
BMC Self Test
BMC Self Test failed
BMC Self Test failed
SensorReadingFailed
SensorReadingFailed': IPMI diagnostics are currently unresponsive
SensorReadingFailed': IPMI diagnostics are currently unresponsive
Input Missing or Out of Range
Power supply PSx input missing or out of range
Power supply PSx input missing or out of range
DriveAvailableWarning
DriveAvailable Warning AutoSupport Message
DriveAvailable Warning AutoSupport Message
Other Resources
- How to remove NVIDIA Drivers from an ESXi hostMon, 18 Aug 2025
- SSL Certificate Chain Contains RSA Keys Less Than 2048 bits reported for H610S BMCMon, 11 Aug 2025
- CVE-2023-48795 SSH Terrapin Attack vulnerability reported for SolidFire and HCI NodesMon, 11 Aug 2025
- Incorrect bond port counts detected on the sipi interfaces of nodesFri, 08 Aug 2025
- The H610S system automatically powers on after connecting the powerFri, 01 Aug 2025
- blockServiceUnhealthy occurred from multiple drivesSun, 13 Jul 2025
- H610S node reboots unexpectedly with critical medium errors on multiple drivesFri, 20 Jun 2025
- Active IQ reports bmcSelPCIeError, and the slot links down and up repeatedlyMon, 09 Jun 2025
- H610S node can't boot with Machine Check Exception(MCERR)Fri, 23 May 2025
- Incorrect node replacement process causes data unavailable with 2nd hardware failureMon, 19 May 2025
- Phantom hard drive found on SolidFire storage nodeTue, 06 May 2025
- SolidFire H410S node reboots unexpectedly with CPU Fatal error - AssertionTue, 24 Dec 2024
- Unable to access H410S IPMI via shared port after power drainThu, 05 Dec 2024
- SF19210-all drives marked as DriveMissing and then moved to available stateTue, 26 Nov 2024
- H610S BMC WebUI can't access after IP changedSat, 23 Nov 2024
- All storage nodes report SensorReadingFailed, bmcTestFailed and not resolved by power drainTue, 15 Oct 2024
- NETWORK_FIRMWARE_VERSION_ETH3 should be >= 0x80000aee but is nullFri, 30 Aug 2024
- One drive has not been detected after H610S node replacementThu, 29 Aug 2024
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issueMon, 26 Aug 2024
- How to set BMC time of H410 series using IPMI WebUIMon, 19 Aug 2024
- SolidFire and HCI Cluster upgrade pre-checks for all upgradesWed, 17 Sep 2025
- AutoSupport Message: Power supply PSx input missing or out of rangeWed, 17 Sep 2025
- IPMI unresponsive and nodeOffline repeatedly after the periodic BMC cold resetFri, 12 Sep 2025
- fileSystemIsReadOnly /var/log is in Read-Only mode alert on Element clusterWed, 10 Sep 2025
- H610S node can not boot with Critical Processor MCERR errorFri, 05 Sep 2025
- Incorrect bond port counts detected on the sipi interfaces of nodesTue, 02 Sep 2025
- Failed drive on Element clusterSat, 30 Aug 2025
- Solid Red information LED on H410S nodeFri, 22 Aug 2025
- How to remove NVIDIA Drivers from an ESXi hostMon, 18 Aug 2025
- SSL Certificate Chain Contains RSA Keys Less Than 2048 bits reported for H610S BMCMon, 11 Aug 2025
- CVE-2023-48795 SSH Terrapin Attack vulnerability reported for SolidFire and HCI NodesMon, 11 Aug 2025
- Compute node details not showing in HCI after scale process failureMon, 11 Aug 2025
- Element UI alert shows "MEMORY_GB should be >= <x> but is <x>"Fri, 08 Aug 2025
- The H610S system automatically powers on after connecting the powerFri, 01 Aug 2025
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element softwareWed, 23 Jul 2025
- File System /var/log has below 5% free spaceWed, 23 Jul 2025
- Drive failed with state NvmeCapacitanceTue, 22 Jul 2025
- Element Plug-In for vCenter hangs indefinitely when adding a clusterFri, 18 Jul 2025
- ASUP_PP SolidFire alert from (Drive Available)Wed, 16 Jul 2025
- SolidFire block drive being ejected from the cluster repetitively (including replacement drives)Tue, 15 Jul 2025