SolidFire Hardware KBs
- Last updated
- Mar 26, 2025
- Save as PDF
SolidFire Hardware KBs
Featured
Unresponsive BMC
Troubleshooting unresponsive BMC on H610S
Troubleshooting unresponsive BMC on H610S
BMC Self Test
BMC Self Test failed
BMC Self Test failed
SensorReadingFailed
SensorReadingFailed': IPMI diagnostics are currently unresponsive
SensorReadingFailed': IPMI diagnostics are currently unresponsive
Input Missing or Out of Range
Power supply PSx input missing or out of range
Power supply PSx input missing or out of range
DriveAvailableWarning
DriveAvailable Warning AutoSupport Message
DriveAvailable Warning AutoSupport Message
Other Resources
- SolidFire H410S node reboots unexpectedly with CPU Fatal error - AssertionTue, 24 Dec 2024
- Unable to access H410S IPMI via shared port after power drainThu, 05 Dec 2024
- SF19210-all drives marked as DriveMissing and then moved to available stateTue, 26 Nov 2024
- H610S BMC WebUI can't access after IP changedSat, 23 Nov 2024
- All storage nodes report SensorReadingFailed, bmcTestFailed and not resolved by power drainTue, 15 Oct 2024
- NETWORK_FIRMWARE_VERSION_ETH3 should be >= 0x80000aee but is nullFri, 30 Aug 2024
- One drive has not been detected after H610S node replacementThu, 29 Aug 2024
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issueMon, 26 Aug 2024
- How to set BMC time of H410 series using IPMI WebUIMon, 19 Aug 2024
- Mellanox Switch no longer accessibleWed, 14 Aug 2024
- ASUP_PP SolidFire Alert from (Drive Available)Wed, 07 Aug 2024
- Where can hardware information about H-series compute node components be found?Thu, 01 Aug 2024
- SolidFire Link down detects continuallyWed, 24 Jul 2024
- Solid Red information LED on H410S nodeWed, 24 Jul 2024
- What is the meaning of the "i" LED on H410S Nodes?Wed, 24 Jul 2024
- How to set BMC time using ipmitool in mNodeTue, 23 Jul 2024
- Converting a 2-Cable VDS Configuration to a 6-Cable VSS ConfigurationWed, 10 Jul 2024
- SolidFire node will not add to the cluster and gives MTU failure errorThu, 16 May 2024
- Nodes stuck in boot loop after power maintenanceFri, 10 May 2024
- How To Upgrade Compute Node FirmwareMon, 29 Apr 2024
- Element UI alert shows "MEMORY_GB should be >= <x> but is <x>"Mon, 31 Mar 2025
- mtuCheckFailure: Failed to send messages between nodes using the maximum configured MTU (9000)Thu, 27 Mar 2025
- BMC SEL error: Volt_P3V_BAT Voltage Lower CriticalWed, 26 Mar 2025
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issueWed, 26 Mar 2025
- "sensorReadingFailed" and "ensembleDegraded" alerts are detectedWed, 26 Mar 2025
- Element Core File Analysis: 'run killed with signal 11 (SIGSEGV) core dump'Wed, 12 Mar 2025
- How to replace a SolidFire Storage node or HCI Storage nodeWed, 05 Mar 2025
- One or more of the SnapMirrorEndpoints is disconnectedTue, 04 Mar 2025
- How to calculate volume usage on SolidFire cluster using APIsFri, 28 Feb 2025
- How to remove slice drives in a MDSS nodeThu, 27 Feb 2025
- Uncorrectable ECC error detected in SEL Log in H610S with BIOS 3B11Tue, 25 Feb 2025
- 'Detected network configuration mismatch on Bond1G/Bond10G' alert on SolidFire nodeThu, 06 Feb 2025
- How to replace an SSD on NetApp SolidFire SF-Series nodeTue, 04 Feb 2025
- NVRAM device warning={capacitor1And2Temperature: xx.xx C}Mon, 03 Feb 2025
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element softwareFri, 31 Jan 2025
- vCenter Alert "Bootbank cannot be found at path '/bootbank'"Thu, 23 Jan 2025
- SolidFire block drive being ejected from the cluster repetitively (including replacement drives)Wed, 22 Jan 2025
- Incorrect bond port counts detected on the Bond10G interface UIMon, 06 Jan 2025
- SolidFire H410S node reboots unexpectedly with CPU Fatal error - AssertionFri, 03 Jan 2025
- Rebranding of H700S nodes to H410SWed, 18 Dec 2024
Most popular
(views)- What is the difference between iDRAC Express and iDRAC Enterprise and how to configure?
- How to use NetCat instead of telnet to check if a port is open
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element software
- How to replace a SolidFire Storage node or HCI Storage node
- SolidFire - How to change the system hostname on iDRAC
- AutoSupport Message: Incorrect bond port counts detected
- Persistent blockClusterFull alerts on Element storage cluster
- SolidFire and HCI Cluster upgrade pre-checks for all upgrades
- How to determine the BIOS version on storage nodes
- AutoSupport Message: Power supply PSx input missing or out of range
- ExcessiveCapacitorVoltage alert on NetApp Element storage nodes
- What are the password requirements for iDRAC and BMC on SolidFire/HCI node?
- Is it possible to how to check MAC address using CLI for iDRAC?
- How to run VAAI UNMAP and return capacity to Element
- How to recover from setup-mnode failures
Highest rated
(rating)- Multiple volumes in a SolidFire cluster offline for several minutes and then come back online with no intervention
- How are the blockSpace thresholds calculated for Element
- AutoSupport Message: driveFailed on Element cluster
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element software
- How to migrate a storage node between NetApp Element clusters
- How does Element Software calculate IOPS and throughput to display in graphical reports?
- SolidFire: Turning off smartd on the ESXi hosts makes the cmd 0x85 and subsequent "state in doubt" messages stop
- Which IOmeter version is supported with Element software?
- SolidFire Bond10G goes down when flapping an interface during troubleshooting
- H610s csaveStatusError alert
- How to verify a SolidFire node is not hosting any volumes
- How to reboot a iDRAC when web page refuse access
- How to send a test SNMP trap
- How to modify SNMP community name value via iDRAC
- H610S Node unresponsive due to a kernel panic
Recently updated
(date updated)- Element UI alert shows "MEMORY_GB should be >= <x> but is <x>"
- mtuCheckFailure: Failed to send messages between nodes using the maximum configured MTU (9000)
- BMC SEL error: Volt_P3V_BAT Voltage Lower Critical
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issue
- "sensorReadingFailed" and "ensembleDegraded" alerts are detected
- Element Core File Analysis: 'run killed with signal 11 (SIGSEGV) core dump'
- How to replace a SolidFire Storage node or HCI Storage node
- One or more of the SnapMirrorEndpoints is disconnected
- How to calculate volume usage on SolidFire cluster using APIs
- How to remove slice drives in a MDSS node
- Uncorrectable ECC error detected in SEL Log in H610S with BIOS 3B11
- 'Detected network configuration mismatch on Bond1G/Bond10G' alert on SolidFire node
- How to replace an SSD on NetApp SolidFire SF-Series node
- NVRAM device warning={capacitor1And2Temperature: xx.xx C}
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element software
Recently added
(date created)- SolidFire H410S node reboots unexpectedly with CPU Fatal error - Assertion
- Unable to access H410S IPMI via shared port after power drain
- SF19210-all drives marked as DriveMissing and then moved to available state
- H610S BMC WebUI can't access after IP changed
- All storage nodes report SensorReadingFailed, bmcTestFailed and not resolved by power drain
- NETWORK_FIRMWARE_VERSION_ETH3 should be >= 0x80000aee but is null
- One drive has not been detected after H610S node replacement
- "sensorReadingFailed" and "ensembleDegraded" alerts due to filesystem issue
- How to set BMC time of H410 series using IPMI WebUI
- Mellanox Switch no longer accessible
- ASUP_PP SolidFire Alert from (Drive Available)
- Where can hardware information about H-series compute node components be found?
- SolidFire Link down detects continually
- Solid Red information LED on H410S node
- What is the meaning of the "i" LED on H410S Nodes?