SolidFire Hardware KBs
SolidFire Hardware KBs
Featured
Unresponsive BMC
Troubleshooting unresponsive BMC on H610S
Troubleshooting unresponsive BMC on H610S
BMC Self Test
BMC Self Test failed
BMC Self Test failed
SensorReadingFailed
SensorReadingFailed': IPMI diagnostics are currently unresponsive
SensorReadingFailed': IPMI diagnostics are currently unresponsive
Input Missing or Out of Range
Power supply PSx input missing or out of range
Power supply PSx input missing or out of range
DriveAvailableWarning
DriveAvailable Warning AutoSupport Message
DriveAvailable Warning AutoSupport Message
Other Resources
- SolidFire node will not add to the cluster and gives MTU failure errorThu, 16 May 2024
- Nodes stuck in boot loop after power maintenanceFri, 10 May 2024
- How To Upgrade Compute Node FirmwareMon, 29 Apr 2024
- Cannot add compute node to clusterTue, 23 Apr 2024
- Can H410C be configured not to shut down when power button is pressed?Mon, 08 Apr 2024
- Network interface eth down or cable is unpluggedThu, 14 Mar 2024
- Drive Active LED does not lit up or blink in SK Hynix drives in H610S nodesFri, 08 Mar 2024
- 500 Internal Server Error on BMC while uploading SSL certificateThu, 22 Feb 2024
- vCenter Alert "Bootbank cannot be found at path '/bootbank"Fri, 19 Jan 2024
- Mellanox SN2010 Ethernet Switch Generating Garbage OutputSat, 06 Jan 2024
- BMC/IPMI IP is unreachable due to faulty portThu, 21 Dec 2023
- H610S Node unresponsive due to a kernel panicThu, 09 Nov 2023
- H610S NVRAM device reports persistenceLostWed, 08 Nov 2023
- Multiple storage nodes shutdown simultaneouslyFri, 27 Oct 2023
- H410s node offline due to Machine Check ExceptionThu, 19 Oct 2023
- Errors are being recorded on the switch side which connects to the SolidFire nodeTue, 17 Oct 2023
- Uncorrectable ECC error detected in SEL Log in H610S with BIOS 3B11Fri, 13 Oct 2023
- H410C node suddenly powers off and will not boot upMon, 09 Oct 2023
- SolidFire power supply LED status is offFri, 06 Oct 2023
- Metadrive frequently goes to available state due to malfunction fan in NVRAMWed, 20 Sep 2023
- Using the IQN to identify Element Software volume connectivityThu, 20 Jun 2024
- Element protection domain does not show the correct value where recilency is lostThu, 20 Jun 2024
- Critical Sensors "Volt_PVCCIN_CPU1" and "Thermal trip" on BMC consoleThu, 20 Jun 2024
- "sensorReadingFailed" and "ensembleDegraded" alerts are detectedMon, 17 Jun 2024
- Active IQ reports "blockServiceUnhealthy" and drive becomes to availableFri, 14 Jun 2024
- One or more of the SnapMirrorEndpoints is disconnectedSat, 08 Jun 2024
- Drive Slot LED blinking amber on H610S without any alerts or events in cluster UIThu, 06 Jun 2024
- SolidFire xAPIMethodFailed : Malformed network configuration on Bond1G: IPv4 or IPv6 Address must be specifiedMon, 03 Jun 2024
- Nmap scan of H610S reports a vulnerability specific to Diffie-Hellman groups with insufficient key strengthFri, 31 May 2024
- Unable to access SolidFire per-node UIFri, 24 May 2024
- NVRAM device warning={capacitor1And2Temperature: xx.xx C}Tue, 21 May 2024
- H610S node can not boot with MCERR errorMon, 20 May 2024
- NetApp HCI compute node does not boot to ESXi automaticallyFri, 17 May 2024
- SolidFire node will not add to the cluster and gives MTU failure errorThu, 16 May 2024
- Element Core File Analysis: Block service restart triggers core dumpWed, 15 May 2024
- Nodes stuck in boot loop after power maintenanceFri, 10 May 2024
- AutoSupport Message: Power supply PSx input missing or out of rangeTue, 07 May 2024
- How To Upgrade Compute Node FirmwareTue, 30 Apr 2024
- Multiple Drives moved to 'Available' pool on Element nodeFri, 26 Apr 2024
- 'SensorReadingFailed': IPMI diagnostics are currently unresponsive on Element softwareWed, 24 Apr 2024