Skip to main content
NetApp Knowledge Base

AutoSupport Message: Call home for Health Monitor process CSHM: UnsupportedSwitch_Alert

Views:
3,028
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9
  • Cluster Switch Health Monitor (CSHM) AutoSupport message

Description

  • This Alert will trigger if:
    • You had a switchless cluster previously configured and was changed to a Switched  configuration
    • You changed the node names in a Switchless configuration.  
  • Below is the system health alert that was generated. The "Alerting Resource" and "Corrective Actions" sections will call out the old/Stale name of the nodes in the cluster.  


Inkedsystem health alert xml_LI.jpg
 

  • EMS will generate the following message during a reboot:

Sun Jun 09 08:44:29 CEST [netapp01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: UnsupportedSwitch_Alert[Old_node_name].

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.