On system reboot, node is reporting "Disk auto-partitioning is disabled on this system: ADP DISABLED."

Views:
4,316
Visibility:
Public
Votes:
3
Category:
ontap-9
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • FAS8200
  • FAS8300
  • AFF A300
  • AFF A400
  • ADPv1
  • SSD and HDD mix configuration in same aggregate

Issue

  • On every node reboot, system reports ADP DISABLED and also generates an Autosupport with the event, even if the system is configured with ADP.

Mar 03 11:05:00 [Node-A:raid.autoPart.disabled:ALERT]: Disk auto-partitioning is disabled on this system: the system needs a minimum of 8 usable internal hard disks.
Mar 03 11:05:00 [Node-A:callhome.raid.adp.disabled:ALERT]: Disk auto-partitioning is disabled on this system: ADP DISABLED.

  • SYSCONFIG-R shows raid group layout do not changed:

Aggregate XXXXXXXX (online, raid_dp, fast zeroed, hybrid) (block checksums)
  Plex /XXXXXXXX/plex0 (online, normal, active, pool0)
    RAID group /XXXXXXXX/plex0/rg0 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0d.02.6     0d    2   6   SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      parity      0a.02.7     0a    2   7   SA:A   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      data        0d.02.8     0d    2   8   SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      data        0a.02.9     0a    2   9   SA:A   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      data        0d.02.10    0d    2   10  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      data        0d.03.2     0d    3   2   SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
      ...
      ..

    RAID group /XXXXXXXX/plex0/rg2 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0c.10.3P1    0c    10  3   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      parity      0b.10.2P1    0b    10  2   SA:B   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      data        0c.10.15P1    0c    10  15  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      data        0c.10.5P1    0c    10  5   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      data        0b.10.8P1    0b    10  8   SA:B   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      data        0c.10.7P1    0c    10  7   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 (fast zeroed)
      ...

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.