- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Why_automatic_disk_copy_from_external_to_internal_shelfAs soon as an internal disk is available as a spare (for instance after the replacement of the failed disk), ONTAP will copy the content of the external disk to the internal spare disk automatically. ...As soon as an internal disk is available as a spare (for instance after the replacement of the failed disk), ONTAP will copy the content of the external disk to the internal spare disk automatically. After the failed 0a.00.11 gets physically replaced by a new disk, ONTAP will start copying the data from the external disk 0b.01.1 to the new internal disk 0a.00.11.
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Disk_bad_label_after_metrocluster_configuration_settings_connection_connectApplies to AFF A220 MetroCluster IP Advanced Disk Partitioning (ADP) Issue Remote drives marked "Bad Label" immediately after running "metrocluster configuration-settings connection connect" Event log...Applies to AFF A220 MetroCluster IP Advanced Disk Partitioning (ADP) Issue Remote drives marked "Bad Label" immediately after running "metrocluster configuration-settings connection connect" Event log reports the following raid.assim.disk.nolabels:EMERGENCY]: Disk XX Shelf X Bay XX [NETAPP X] S/N [X] UID [X] has no valid labels. It will be taken out of service to prevent possible data loss.
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Unable_to_assign_remote_disks_during_MetroCluster_IP_configurationApplies to ONTAP 9 MetroCluster IP AFF-A320 One NS224 shelf per site Advanced Disk Partitioning (ADP) Issue When trying to assign the remote disks during MetroCluster IP configuration, an error messag...Applies to ONTAP 9 MetroCluster IP AFF-A320 One NS224 shelf per site Advanced Disk Partitioning (ADP) Issue When trying to assign the remote disks during MetroCluster IP configuration, an error message similar to the below is displayed: Cluster01::*> disk assign -pool 1 -owner Local-01 -disk Local-01:0m.i0.7L7 Error: command failed: Failed to assign disks. Reason: Cannot assign "0m.i0.7L7" from this node. Try the command again on node "Remote-01" (<Sys-ID>).
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/What_are_the_steps_followed_to_configure_advanced_drive_partitioning_from_ONTAP_boot_menu_option_9This menu option erases ALL data on the disks of the node and HA partner when partitions are shared between node and HA partner as well resets your node configuration to the factory default settings. ...This menu option erases ALL data on the disks of the node and HA partner when partitions are shared between node and HA partner as well resets your node configuration to the factory default settings. Beginning with ONTAP 9.2, a new Advanced Drive Partitioning option is available from the Boot Menu ( Managing a node by using the boot menu ) that provides additional management features for disks that are configured for root-data or root-data-data partitioning.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/System_install_failed_with_Auto_partitioning_is_disabled_on_this_system__the_system_needs_a_minimum_of_8_internal_hard_disksApplies to ONTAP 9 Issue During the install or initialization (option 4 from boot menu), a message similar to the following was displayed: Auto-partitioning is disabled on this system: the system need...Applies to ONTAP 9 Issue During the install or initialization (option 4 from boot menu), a message similar to the following was displayed: Auto-partitioning is disabled on this system: the system needs a minimum of 8 internal hard disks. Auto-partitioning is disabled on this system: the system needs a minimum of 4 usable internal hard disks.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Unable_to_re-initialize_system_with_ADPThis menu option erases ALL data on the disks of the node and HA partner when partitions are shared between node and HA partner as well resets your node configuration to the factory default settings. ...This menu option erases ALL data on the disks of the node and HA partner when partitions are shared between node and HA partner as well resets your node configuration to the factory default settings. cryptomod_fips: Crypto FIPS self-test: 'AES-128 ECB, AES-256 ECB' passed. cryptomod_fips: Crypto FIPS self-test: 'AES-128 CBC, AES-256 CBC' passed. cryptomod_fips: Crypto FIPS self-test: 'AES-128 GCM, AES-256 GCM' passed. cryptomod_fips: Crypto FIPS self-test: 'AES-128 CCM' passed.
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/MetroCluster_IP_installation_on_FAS_fails_with_disk.partDiskNotSuppMCC_messageApplies to MetroCluster IP FAS platforms Console messages Ignoring disk <diskname> because partitioned disks are not supported in a MetroCluster(TM) configuration. Issue When installation MetroCluster...Applies to MetroCluster IP FAS platforms Console messages Ignoring disk <diskname> because partitioned disks are not supported in a MetroCluster(TM) configuration. Issue When installation MetroCluster IP on a FAS system the system displays the following error message: Jan 26 21:43:06 [localhost:disk.partDiskNotSuppMCC:notice]: Ignoring disk <diskname> because partitioned disks are not supported in a MetroCluster(TM) configuration.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Recover_broken_ADP_partitionsContainer-type listed as broken for one or more partitions: Cluster1::*> disk partition show -container-type broken 1.20.13.P1 1.68TB broken - Node1 1.20.14.P1 1.68TB broken - Node1 1.20.21.P1 1.68TB ...Container-type listed as broken for one or more partitions: Cluster1::*> disk partition show -container-type broken 1.20.13.P1 1.68TB broken - Node1 1.20.14.P1 1.68TB broken - Node1 1.20.21.P1 1.68TB broken - Node1 1.20.21.P3 143.7GB broken - Node1 1.20.22.P1 1.68TB broken - Node1 1.20.22.P3 143.7GB broken - Node1 2.21.18.P1 1.68TB broken - Node1 2.21.18.P3 143.7GB broken - Node1 2.21.19.P1 1.68TB broken - Node1 2.21.19.P3 143.7GB broken - Node1
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_add_disks_to_a_new_partitioned_raidgroup_in_a_partitioned_aggregateApplies to Systems using partitioned disks/SSD's ADPv1 or ADPv2 Aggregate expansion Description When adding non-partitioned spare disks to a partitioned aggregate as a new RAID group, the non-partitio...Applies to Systems using partitioned disks/SSD's ADPv1 or ADPv2 Aggregate expansion Description When adding non-partitioned spare disks to a partitioned aggregate as a new RAID group, the non-partitioned spares are not automatically getting partitioned as expected in the new RAID group Follow the steps provided to partition 1 non-partitioned spare , first This will allow you to add the remaining non-partitioned spares
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/On_every_node_reboot_system_is_reporting_ADP_DISABLEDOn every node reboot, system reports ADP DISABLED and also generates an Autosupport with the event, even if the system is configured with ADP. Mar 03 11:05:00 [Node-A:raid.autoPart.disabled:ALERT]: Di...On every node reboot, system reports ADP DISABLED and also generates an Autosupport with the event, even if the system is configured with ADP. Mar 03 11:05:00 [Node-A:raid.autoPart.disabled:ALERT]: Disk auto-partitioning is disabled on this system: the system needs a minimum of 8 usable internal hard disks. Mar 03 11:05:00 [Node-A:callhome.raid.adp.disabled:ALERT]: Disk auto-partitioning is disabled on this system: ADP DISABLED.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Unable_to_add_expected_capacity_to_aggregate_using_partitioned_disksApplies to ONTAP 9 Hardware with Advanced Disk Partitioning (ADP) Issue Disks are of smaller size and total capacity is less than expected after adding available disks to aggregate.