  • ONTAP 9
  • SP firmware update

Answer

  • The auto-update mechanism depends on whether the auto-update option is enabled.
  • When a replacement motherboard has a lower BMC firmware version than the original, ONTAP attempts SP/BMC firmware auto-update up to three times; if all attempts fail, no further retries occur, and a manual update is required.
  • If the replacement motherboard has a newer firmware version, ONTAP does not perform a downgrade. In this case, the partner node should be updated to match the same SP firmware version.

Additional Information

additionalInformation_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.