Image update errors during SP/BMC Firmware upgrade
Applies to
- ONTAP 9
- Service Processor
Description
- The
system health subsystem show
output shows the Service-Processor as degraded:
::> system health subsystem show
Subsystem
Health
----------------- ------------------
Environment ok
Memory ok
Service-Processor degraded
Switch-Health ok
CIFS-NDO ok
Motherboard ok
::> system health alert show
Node | cluster1-01 |
---|---|
Monitor | controller |
Alert ID | SPAutoUpgradeFailedMajorAlert |
Alerting Resource | SP Upgrade |
Subsystem | Service-Processor |
Perceived Severity | Major |
Probable Cause | Configuration_error |
Description | A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. |
Corrective Actions |
|
Possible Effect | Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package. |
- Verify if an upgrade is currently in progress:
::> service-processor image update-progress show
- Check EMS for any errors
::> event log show -node node-01 -event sp.*
Note: Make sure to check the following guide Service Processor (SP) and Baseboard Management Controller (BMC) upgrade troubleshooting