Flash Cache NVMe Exhausted - AutoSupport Message
Applies to
- ONTAP 9
- callhome.nvme.exhausted:alert
Event Summary
- This message occurs when a flash cache device has reached end of life
Validate
Call home event
FLNVME:HA Group Notification from Node Name (Flash Cache NVMe Exhausted) ALERT
EMS Log
- Run
event log show -severity * -message-name callhome*
Sat Mar 12 13:12:12 +0100 [Node Name: gemini-notif-thread: callhome.nvme.exhausted:alert]: Callhome for Flash Cache NVMe Exhausted.
Command Line
- Run
system node run -node <node name> -command sysconfig
slot 1: Flash Cache NVMe
Serial Number: XXXXXXXX
Part Number: 119-00329
Hardware Revision: A0
Firmware Version: NA03
Firmware File: X3311_S00005000NVM
Model Name: X3311A
Capacity: 1024 GB
State: failed
Resolution
- Please contact NetApp Technical Support and reference this article for further assistance. The solution might require a part replacement.
Additional Information
- If firmware version of the device aforementioned is lower than NA03, it needs to be updated using How to update an offline NVMe Flash Cache