Skip to main content
NetApp Knowledge Base

FAS26xx and FAS27xx controller running in Single-Path HA with no external shelf

Views:
1,249
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS26xx/AFF-A200
  • FAS27xx/AFF-C190/AFF-A220

Issue

FAS26xx or FAS27xx system with no external disk shelves, the user may notice that the system is operating in Single-Path HA mode when checked in sysconfig -a
NetApp Release 9.9.1: Sun Jun 13 07:48:38 EDT 2021
	System ID: xxxxxxxxxx (xxxxxxxxxx); partner ID: xxxxxxxxxx(xxxxxxxxxx)
	System Serial Number: xxxxxxxxxxxx (xxxxxxxxxx)
	System Rev: D0
	System Storage Configuration: Single-Path HA
	System ACP Connectivity: Inband Active
	SAS2/SAS3 Mixed Stack Support: all
	All-Flash Optimized: false
	Capacity Optimized: false
	All SAN Array: false
	Backplane Part Number: DS21212
	Backplane Rev: 
	Backplane Serial Number: xxxxxxxxxxxx
	slot 0: System Board 1.5 GHz (System Board XXII D0)
                Model Name:         FAS2720
                Part Number:        111-04333
                Revision:           D0
                Serial Number:      xxxxxxxxxxxx
                BIOS version:       11.11
                Loader version:     6.0.12
                Processors:         12
                Processor ID:       0x50664
                Microcode Version:  0xf000016
                Processor type:     Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz
                Memory Size:        32768 MB
                Memory Attributes:  Hoisting
                                    Rank Interleaving
                                    Channel Interleaving
                Mezzanine Card:     
                    Part:           111-04160
                    Version:        A1
                    Serial:         xxxxxxxxxxxx
                NVMEM Size:         4094 MB of Main Memory Used
                Controller:         A
                PCIE Switch 1:      id 1 546 1.04
                TPM FW Version:     5.63.3353.0
	Service Processor           Status: Online
		Firmware Version:   11.6
		Mgmt MAC Address:   xx:xx:xx:xx:xx:xx
		Ethernet Link:      up, full duplex, auto-neg complete
		Using DHCP:         no
	IPv4 configuration:
		IP Address:         xxx.xxx.xxx.xxx
		Netmask:            xxx.xxx.xxx.xxx
		Gateway:            xxx.xxx.xxx.xxx
	IPv6 configuration:         Disabled
	[Service Processor cached network information determined at Tue Dec 14 07:57:40 UTC 2021]

	slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <OFFLINE (hard)>)
		Firmware rev:       03.08.09.00
		Base WWN:           5:00a098:00e8102:b0
		Temperature:        Not Available
		Phy State:          [0] Disabled
		                    [1] Disabled
		                    [2] Disabled
		                    [3] Disabled
		Mini-SAS HD Vendor:        not available
		Mini-SAS HD Part Number:   not available
		Mini-SAS HD Type:          not available
		Mini-SAS HD Serial Number: not available
	slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
		Firmware rev:       03.08.09.00
		Base WWN:           5:00a098:00e8102:b4
		Temperature:        Not Available
		Phy State:          [4] Enabled, 12.0 Gb/s
		                    [5] Enabled, 12.0 Gb/s
		                    [6] Enabled, 12.0 Gb/s
		                    [7] Enabled, 12.0 Gb/s
		00.0 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.1 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.2 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.3 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.4 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.5 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.6 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.7 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.8 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.9 : NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.10: NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		00.11: NETAPP   X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
		Shelf 0: DS212-12  Firmware rev. IOM12E A: 0230  IOM12E B: 0230

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.