Search
- Filter results by:
- View attachments
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/disk_name_incorrect_display_after_disk_replacementHow to fix 'storage disk show' and System Manager showing incorrect disk name.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/FAS9000_Emergency_shutdown_after_IO_card_changed_from_40Gb_NIC_to_32Gb_FC_HBAPower off node, replace the 40Gb NIC in slot 1 with a 32Gb FC HBA. After power on, ONTAP prompts chassis temperature is too high then emergency shutdown the node. Dec 29 11:55:19 [node-02:monitor.shut...Power off node, replace the 40Gb NIC in slot 1 with a 32Gb FC HBA. After power on, ONTAP prompts chassis temperature is too high then emergency shutdown the node. Dec 29 11:55:19 [node-02:monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Temp on I/O Slot1 is critical high. Dec 29 11:57:19 [node-02:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Multiple_instances_of_scsi.cmd.pastTimeToLive_messages_after_FAS8300_add_IOM6_shelfMini-SAS HD Part Number: 112-00431+A0 Mini-SAS HD Type: Passive Copper (unequalized) 5m end_0 Mini-SAS HD Serial Number: 011431565 01.0 : NETAPP X477_TTCRE04TA07 NA02 3807.8GB 520B/sect (37B0A04HF9XC)...Mini-SAS HD Part Number: 112-00431+A0 Mini-SAS HD Type: Passive Copper (unequalized) 5m end_0 Mini-SAS HD Serial Number: 011431565 01.0 : NETAPP X477_TTCRE04TA07 NA02 3807.8GB 520B/sect (37B0A04HF9XC) 01.1 : NETAPP X477_TTCRE04TA07 NA02 3807.8GB 520B/sect (37B0A04LF9XC) 01.2 : NETAPP X477_TTCRE04TA07 NA02 3807.8GB 520B/sect (37B0A04MF9XC) <output truncated> 07.19: NETAPP X477_SMKRE04TA07 NA01 3807.8GB 520B/sect (Z4F1G82Q) 07.20: NETAPP X477_SMKRE04TA07 NA01 3807.8GB 520B/sect (Z4F1GGLG) 07.21: …
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/False_SPNotConfiguredAlert_with_SP_5.7Applies to FAS/AFF Service Processor (SP) Baseboard Management Console (BMC) Issue system controller show reports controller status is degraded. The health monitor triggers the following alert frequen...Applies to FAS/AFF Service Processor (SP) Baseboard Management Console (BMC) Issue system controller show reports controller status is degraded. The health monitor triggers the following alert frequently and clears it: [nphmd: hm.alert.raised:alert]: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config raised by monitor controller [nphmd: hm.alert.cleared:notice]: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config cleared by monitor controller
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/FAS26xx_and_FAS27xx_controller_running_in_Single-Path_HA_with_no_external_shelfC, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e8102:b4 Temperature: Not Available Phy State: [4] Enabled, 12.0 Gb/s [5] Enabled, 12.0 Gb/s [6] Enabled, 12.0 Gb/s [7] Enabled, 12.0 Gb/s ...C, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e8102:b4 Temperature: Not Available Phy State: [4] Enabled, 12.0 Gb/s [5] Enabled, 12.0 Gb/s [6] Enabled, 12.0 Gb/s [7] Enabled, 12.0 Gb/s 00.0 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx) 00.1 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx) 00.2 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx) 00.3 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx) 00.4 : NETAPP X318_SCMNE08TA07 NA00…
- https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Brocade_management_UI_unreachable_via_SSH_WEB_SNMPApplies to Brocade SAN Switch FOS version lower than v8.2.3a Issue Brocade switch management IP can be pinged. But the SSH window will disappears after entering the username and password, and the web ...Applies to Brocade SAN Switch FOS version lower than v8.2.3a Issue Brocade switch management IP can be pinged. But the SSH window will disappears after entering the username and password, and the web GUI cannot be opened. ONTAP trigger Health Monitor process schm: FabricSwitchUnreachable_Alert Only can execute commands via console port.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/environment_sensors_show_command_returns_Warning__Unable_to_list_entries_on_nodeApplies to ONTAP 9 Service Processor(SP) Issue The following errors occur when executing system node environment sensors show command. cluster::> system node environment sensors show Warning: Unable t...Applies to ONTAP 9 Service Processor(SP) Issue The following errors occur when executing system node environment sensors show command. cluster::> system node environment sensors show Warning: Unable to list entries on node nodename. System busy: 7 requests on table "spcc_sp_get_sensor_info" have been pending for 937227 seconds. Error: show failed: System busy: 7 requests on table "spcc_sp_get_sensor_info" have been pending for 937227 seconds. The last completed call took 0 seconds.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Switch_log_collection_fails_switch_log_scp_error_switch_mgmt_port_running_at_100MbsApplies to ONTAP 9 Cisco cluster switch switch health monitor log collection Issue SCP on each Cisco Switch is enabled. Switch log collection is failed with error message "switch log scp error"
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Jabber_errors_on_ethernet_portRECEIVE Total frames: 2233m | Frames/second: 247 | Total bytes: 571g Bytes/second: 63198 | Total errors: 11352k | Errors/minute: 75 Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 1962m Non-...RECEIVE Total frames: 2233m | Frames/second: 247 | Total bytes: 571g Bytes/second: 63198 | Total errors: 11352k | Errors/minute: 75 Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 1962m Non-primary u/c: 0 | Errored frames: 0 | Unsupported Op: 0 CRC errors: 0 | Runt frames: 0 | Fragment: 0 Long frames: 4601 | Jabber: 11347k | Length errors: 0
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Controller_fault_LED_ON_with_PCI_error_recorded_in_SRAMAll FAS Platform Controller fault LED ON system controller service-event show that PCI error recorded in SRAM on PCIE-3 Check sysconfig -a slot 3 Flash Cache status is ok, and FW is the latest version...All FAS Platform Controller fault LED ON system controller service-event show that PCI error recorded in SRAM on PCIE-3 Check sysconfig -a slot 3 Flash Cache status is ok, and FW is the latest version. sysconfig -a: slot 3: Flash Cache NVMe Serial Number: S3K6NX0K202085 Part Number: 119-00329 Hardware Revision: A0 Firmware Version: NA03 Firmware File: X3311_S000PM963NVM Model Name: X3311A Capacity: 1024 GB State: ok event log show no any error message about Flash Cache sp event log was good
- https://kb.netapp.com/Legacy/NetApp_HCI/OS/HCI_compute_node_stops_with_hardware_related_RTFI_HARDWARE_FAILURES_error_during_RTFIApplies to NetApp HCI H615C compute node Return to Factory Image (RTFI) Issue RTFI of HCI compute node stops with the following error: [NUM_DRIVES_INTERNAL] mismatch -- actual=[1] >= expect=[2] There ...Applies to NetApp HCI H615C compute node Return to Factory Image (RTFI) Issue RTFI of HCI compute node stops with the following error: [NUM_DRIVES_INTERNAL] mismatch -- actual=[1] >= expect=[2] There are 1 hardware related RTFI_HARDWARE_FAILURES hardware_check failed