- https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/How_to_power_DOWN_and_power_UP_an_E-Series_storage_systemThis article describes how to power off and on an E-Series array. Situations in which this process maybe applicable are: when moving the system to a new location, data center upgrades, hardware repla...This article describes how to power off and on an E-Series array. Situations in which this process maybe applicable are: when moving the system to a new location, data center upgrades, hardware replacement, or upgrades.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/System_does_not_start_after_reboot_due_to_Unable_to_recover_the_local_database_of_Data_Replication_ModuleEMS log shows: NODE_B:rdb.recovery.failed:EMERGENCY]: Error: Unable to find a master. Unable to recover the local database of Data Replication Module: Management
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Why_raid_timeout_option_doesn_t_avoid_a_environmental_shutdownBug 1466540 - ONTAP ignores the "raid.timeout" option for NV battery events that trigger a shutdown Environmental NVRAM battery full-charge capacity errors are not controlled by the raid.timeout optio...Bug 1466540 - ONTAP ignores the "raid.timeout" option for NV battery events that trigger a shutdown Environmental NVRAM battery full-charge capacity errors are not controlled by the raid.timeout option. [node_name: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity low) Bug 1226107 Feature request: SP/BMC support for system environmental shutdown configuration in ONTAP
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_shut_down_an_Element_storage_node_for_maintenance_using_Healthtools_sfinstallApplies to NetApp SolidFire NetApp Element Software 12.0 and Below NetApp HCI H Series storage nodes SF Series storage nodes Element Management Node (mNode) This article explains the procedure to shut...Applies to NetApp SolidFire NetApp Element Software 12.0 and Below NetApp HCI H Series storage nodes SF Series storage nodes Element Management Node (mNode) This article explains the procedure to shut down an Element storage node for maintenance using HealthTools (specifically, the sfinstall CLI tool on the Management Node (mNode)). Note: In Element versions 12.2 and above, the same can be accomplished directly via API methods as documented in How to use Maintenance Mode in Element Software.
- https://kb.netapp.com/on-prem/ontap/DM/System_Manager/SM-KBs/Can_System_Manager_reboot_node_in_single_node_clusterApplies to ONTAP System Manager 9.8 or later Answer System Manager does not show Reboot menu, so use system node reboot command instead. Additional Information System Manager shows the following actio...Applies to ONTAP System Manager 9.8 or later Answer System Manager does not show Reboot menu, so use system node reboot command instead. Additional Information System Manager shows the following actions in CLUSTER -> Overview Single-node cluster: Two-node cluster:
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/AFF_A400_FAS8700_and_FAS8300_reboot_with_CHASSIS_OVER_TEMPERATURE_SHUTDOWN_EMERGENCY_due_to_low_memoryCX5_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na CX5_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na RiserL_Temp1 | na | degrees C | na | na | 0.000 ...CX5_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na CX5_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na RiserL_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na RiserL_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na CPU0_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na CPU1_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na
- https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_gracefully_shut_down_and_power_on_a_NetApp_Solidfire_HCI_storage_clusterApplies to NetApp Element software NetApp Solidfire NetApp HCI Description This article describes how to gracefully shut down all the storage nodes within a cluster running NetApp Element with an API ...Applies to NetApp Element software NetApp Solidfire NetApp HCI Description This article describes how to gracefully shut down all the storage nodes within a cluster running NetApp Element with an API call Note: This will not affect nodes that are in the pending state
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_reboot_following_multi_sensor_failures_due_to_unconfigured_console_server_or_dangling_cable[Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanA1 F1 at failed [Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one ...[Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanA1 F1 at failed [Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanA1 F2 at failed [Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanA1 F3 at failed [Node-1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanA1 F4 at failed
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Environment_shutdown_due_to_a_FAN_failure_in_a_FAS_9000Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F1 at failed Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chas...Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F1 at failed Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F2 at failed Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F3 at failed