Drive Bypassed Causing Controller to Enter a Mixed-Path State
Applies to
- I/O module (IOM) - 3
- I/O module (IOM) - 6
- I/O module (IOM) - 12
- I/O embed module (IOM-E)
- ONTAP 9
Issue
- Disk is bypassed and goes missing from
SYSCONFIG -A
output. - EMS error example:
Mon Nov 23 14:43:22 CET [node1: dsa_worker4: ds.sas.hostphy.disableErr:critical]: [ 7 ] on channels 0b shelf id 22 IOM B Disabled due to excessive invalid dword error.
- SAS-EXPANDER-PHY-STATE, drive reports
Disabled/[reason].
Example:Expander phy state on 0b.22 (NETAPP :DS224IOM6 1200345678):
Pwr Invald Disprt Loss Phy CRC Phy
Pwr Ccl Rsv Rls DWord Error Sync Reset Error Change SATA
PHY/BAY STATE ON Cnt Cnt Cnt Count Count Count Prob Cnt Cnt Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
15/7 Disabled/IDD YES 0 0 0
21/13 Disabled/BRST_PCD YES 3 0 0 - Mixed-Path storage system state example:
::>system node run -node <nodename> -command sysconfig -a
NetApp Release 9.5P2: Thu Mar 14 10:01:49 EDT 2019
System ID: 0123456789 (NODE-01); partner ID: 0123456788 (NODE-02)
System Serial Number: 0123456789012 (NODE-01)
System Rev: A4
System Storage Configuration: Mixed-Path
...