"Failed Disk Drawer" Drawers Control Module reports "NONCRITICAL, REPORT, PATH FAIL"
Applies to
- ONTAP 9
- DS460C
Issue
- EMS reports
[node01: dsa_worker5: ds.sas.hostphy.disableErr:alert]: Port [DCM2-2] on channels 9b shelf ID 12 IOM B disabled due to excessive invalid dword error.
[node01: dsa_worker5: callhome.hostport.disable:alert]: Call home for HOST_PORT_FAIL - Disabled by IOM
[node01: monitor: monitor.globalStatus.critical:EMERGENCY]: There are not enough spare disks. Assign unowned disks. Disk shelf fault.
[node01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 10a. Check fans, power supplies, disks, and temperature sensors.
[node01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "33", module "B", drawer "4", PHY "12" is reporting an unknown link rate.
- AutoSupport
STORAGE-FAULT
shows Drawers Control Module reports "NONCRITICAL, REPORT, PATH FAIL
".
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
...
Drawers Control Module:
Element Status Status
Bytes Status Descriptions
1 [IOM12 A] : NONCRITICAL 03,00,11,00 REPORT, PATH FAIL
2 [IOM12 A] : OK 01,00,01,00 REPORT