CRC errors on a data port connected to a Cisco switch
Applies to
- FAS Systems
- AFF Systems
- Cisco switch
- Active IQ Digital Advisor
Issue
- An Active IQ Risk alert is received:
Risk: This system has a high count of CRC errors accumulated on at least one data network port that should be investigated.
Description: This system has CRC errors on data port e0e.
Impact: High CRC errors counts, or link resets can result in packet loss and are typically caused by physical defects in the port, SFP, or cables
- The port is connected to a Data Switch
IFSTAT-A
section of AutoSupport orcluster::> ifstat -a
reveals CRC errors:
-- interface e0e (1 day, 1 hour, 11 minutes, 41 seconds) --
RECEIVE
Total frames: 6821k | Frames/second: 75 | Total bytes: 6681m
Bytes/second: 73660 | Total errors: 151 | Errors/minute: 0
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 254k
Non-primary u/c: 0 | CRC errors: 151 | Runt frames: 0
Long frames: 0 | Length errors: 0 | Alignment errors: 0
No buffer: 0 | Pause: 0 | Jumbo: 0
Noproto: 0 | Bus overruns: 0 | LRO segments: 399m
- SFP is replaced on both sides
- Cable between node and switch is replaced
- The stats on the node port are cleared, CRC errors return
::>run -node * ifstat -z e0e