Applies to ONTAP 9 CIFS Issue CIFS share names created in uppercase show as lowercase when accessing the CIFS server through IP, but uppercase through FQDN or NETBIOS. Share name in uppercase on Syste...Applies to ONTAP 9 CIFS Issue CIFS share names created in uppercase show as lowercase when accessing the CIFS server through IP, but uppercase through FQDN or NETBIOS. Share name in uppercase on System Manager: Share shows as lowercase when accessing the CIFS server through IP: Share shows as uppercase when accessing the CIFS server through FQDN or NETBIOS:
In this scenario, if one of the cluster ports goes down on one node, then that cluster interconnect link goes down on both the nodes at the same time. Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.c...In this scenario, if one of the cluster ports goes down on one node, then that cluster interconnect link goes down on both the nodes at the same time. Tue Jul 27 02:24:24 IST [Node-1: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0a on node Node-1 has gone down unexpectedly The cluster LIFs hosted on the down cluster ports will be moved to the redundant cluster ports on both nodes.
Applies to SnapManager for Hyper-V (SMHV) SnapDrive for Windows (SDW) Issue SMHV fails to restore a VM in SAN environment. Windows Application Event Log reports the following error. Error description:...Applies to SnapManager for Hyper-V (SMHV) SnapDrive for Windows (SDW) Issue SMHV fails to restore a VM in SAN environment. Windows Application Event Log reports the following error. Error description: Clone operation failed to start: FlexClone files must be autodeletable when the volume's existing space-slo setting is 'semi-thick'. Try the command again with the '-autodelete' parameter...
Applies to ONTAP 9 FPolicy Varonis Issue Varonis is unable to access port 443 and results in communication error due to LIF service policy blocking the FPolicy server
Thu Feb 18 02:15:06 JST [node2: monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of node1 is not possible: unsynchronized log. The interconnect port is at suboptimal speed. Inter...Thu Feb 18 02:15:06 JST [node2: monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of node1 is not possible: unsynchronized log. The interconnect port is at suboptimal speed. Interconnect Port 1: Port Name: ib0a Data Rate: 10 Gb/s (4X) SDR Interconnect Port 2: Port Name: ib0b Active MTU: 4096 Data Rate: 40 Gb/s (4X) QDR Link State: ACTIVE QSFP Vendor: Molex Inc. QSFP Part Number: 112-00374+A0 QSFP Type: Active Optical 5m ID:00 QSFP Serial Number: xxxxxxxxxxxxxx
Multiple switch ports on a slot in Hard_Flt state and DMA errors observed under errdump 2021/07/16-16:29:17:868300, [C4-5351], 86139/0, SLOT 1 | CHASSIS, CRITICAL, SWITCH_X6-4, LKSM [OID 0x43428039] (...Multiple switch ports on a slot in Hard_Flt state and DMA errors observed under errdump 2021/07/16-16:29:17:868300, [C4-5351], 86139/0, SLOT 1 | CHASSIS, CRITICAL, SWITCH_X6-4, LKSM [OID 0x43428039] (065) (S4,BP57): Port to be faulted due to busy buffer stuck error, OID:0x43428039, proto_lksm.c, line: 1708, comp:emd, ltime:2021/07/16-16:29:17:867995
Some important points to consider when subscribing to multiple EMS events in Active IQ Unified Manager: At this time, Active IQ Unified Manager requires a full message name. Refer to the following art...Some important points to consider when subscribing to multiple EMS events in Active IQ Unified Manager: At this time, Active IQ Unified Manager requires a full message name. Refer to the following articles for more setup information about EMS-based event subscriptions in Active IQ Unified Manager: How to identify EMS events for subscription in Active IQ Unified Manager How to configure and receive alerts from ONTAP EMS Event Subscription in Active IQ Unified Manager
Applies to NetApp HCI NetApp SolidFire Active IQ (AIQ) Issue After HCI cluster is migrated from old vCenter instance to new vCenter instance, AIQ shows duplicate compute nodes.
Applies to MetroCluster FC MetroCluster IP Description This article explains how to identify which switch firmware releases are supported in a MetroCluster.
OnCommand Unified Manager provides a centralized location to configure EMS Subscriptions and send notifications. How to identify EMS events for subscription in Active IQ Unified Manager How to configu...OnCommand Unified Manager provides a centralized location to configure EMS Subscriptions and send notifications. How to identify EMS events for subscription in Active IQ Unified Manager How to configure and receive alerts from ONTAP EMS Event Subscription in Active IQ Unified Manager Frequently Asked Questions (FAQs) and Troubleshooting KB Articles for ActiveIQ Unified Manager ONTAP EMS subscription based events